8. INSTALL STEERING OUTPUT HOSES TO
THE COUNTERBALANCE VALVE
Hoses
(P)
are first connected to the left and right steering ports on the orbital steering valve with the other
end connected to ports V1 and V2 of the counterbalance valve
(F)
. The two hoses
(O)
from the A and B
ports of the FieldPilot Valve
(E)
are now connected to the ends of the Run Tee adapters installed on ports
C1 and C2 of the counterbalance valve
(F)
. Finally, the two original hoses removed from the left and right
steering ports on the orbital steering valve are connected to the branches of the two Run Tee fittings on the
C1 and C2 ports of the counterbalance valve
(F)
.
Figure 1-14: Install Steering Output Hoses
V1
C1
V2
C2
This completes the hydraulic kit installation. Be sure all fittings are tight and all hoses are supported Also