Start
To begin the programming process:
☛
Read above for programming tips.
☛
Be sure the Master switch is “OFF.”
☛
Turn console “ON” by pressing the Pro key. When the Control Console is turned on, the
software version will be displayed for approximately 5 seconds. The software version and
serial number of the console will be needed when calling for service support. The serial
number is located on a sticker on the back of the console.
814-AB US V2.10A
Example: the 814-AB airblast monitor is working in US units and the software version is
V2.10A.
☛
After a short time the console will change to the normal monitor mode. The first monitored
value is the working width.
10.0 ft
A
DJUSTING
T
HE
W
ORKING
W
IDTH
Default = 10 ft. (3 m )
10.0 ft
➽
While in the normal monitoring mode, the display selected must be the working width.
➽
Be sure that the Master switch is in the OFF position.
➽
Then press the Pro key once.
10.0 ft <-O->
The working width display will then be flashing. The value can now be adjusted using the Up
and Down keys.
Once the value has been adjusted, return to the normal monitoring mode by pressing the Pro
key once.