SOFTWARE INFO
The current operating software version number for the TeeJet 500 Slurry computer
can be seen.
TEST
TEST INPUT
Test input can be used if a sensor is suspected defect
Directly under each input description, to the right, is a counter that registers the
number of time the input has been activated (the counter is reset automatically
each time “Test input” is exited or by pressing the C key). On the left-hand side
the actual status of the input is shown (Hi/Lo).
All of the different inputs can been seen by pressing the ARROW UP and ARROW
DOWN keys to page through the 3 screens.
The different input descriptions relate to the following:
Input
Description
Wheel
Forward speed signal from the sensor fitted on the tractor
(via the 7-pin DIN/ISO socket fitted in the tractor).
Radar
Forward speed signal from the radar fitted on the tractor
(via the 7-pin DIN/ISO socket fitted in the tractor).
Wheel
implement
Forward speed signal from the sensor fitted on the slurry spreader.
Press the ARROW DOWN key to see the next inputs:
PTO
Rpm signal from the sensor fitted to the PTO shaft.
Flow
Signal from the flow meter.
Press the ARROW DOWN key to see the next inputs:
Rpm pump
Rpm signal from the sensor fitted to the pump.
Rpm
distributor
Rpm signal from the sensor fitted to the distributor.
Implement
Implement signal (area ON/OFF) from the implement sensor fitted
to the tractor (via the 7-pin DIN/ISO socket fitted in the tractor).
TEST OUTPUT
Each individual output can be tested. Press the program key number for the
following test:
Output
Description
Rate +
Program key 1 opens the regulation unit.
Rate -
Program key 2 shuts the regulation unit.