FORWARD SPEED CALIBRATION
The forward speed sensor can be selected and the calibration figure is encoded
here.
It is also possible to calibrate the forward speed sensor and the procedure for this
follows:
Key
Description
Using this key (program key 1) selects the radar as the forward
speed sensor (via the 7-pin DIN/ISO socket).
If the number of pulses per 100 m is known then this can be
encoded directly.
Using this key (program key 2) selects the wheel sensor fitted to the
tractor as the forward speed sensor (via the 7-pin DIN/ISO socket).
If the number of pulses per 100 m is known then this can be
encoded directly.
Using this key (program key 3) selects the wheel sensor fitted to the
slurry spreader as the forward speed sensor.
If the number of pulses per 100 m is known then this can be
encoded directly.
Automatic forward speed calibration:
Step/Key
Description
1
Measure a 100 metre stretch in the field and drive to the start mark.
2
Select the forward speed sensor as described above.
3
Press this key and drive the 100 metre stretch.
Stop exactly at the stop mark.
The TeeJet 500 Slurry computer counts pulses whilst the machine
is driving.
4