LURRY COMPUTER OPERATORS MANUAL

S

ETTINGS

15

TANK VOLUME

Encode the slurry spreader tank size in tons or M

3

here. This setting is necessary

if the “Empty tank” function is to be used (see page 13).

DRIVE FACTOR

The drive factor expresses the speed at which the regulation system works.
If the regulation is too slow then increase the drive factor.
If the regulation is too fast (rate jumps up and down) then decrease the drive
factor.
Standard setting = 25 (as a start figure).

RPM SENSOR

The number of pulses per revolution must be encoded for the following RPM
sensors to ensure that the displayed RPM speed is correct:

PTO:

The number of pulses per revolution for the rpm sensor fitted to the
tractors power take-off shaft (PTO).

Pump:

The number of pulses per revolution for the rpm sensor fitted to the
slurry spreader pump.

Distributor:

The number of pulses per revolution for the rpm sensor fitted to the

distributor.

REGULATION TIME

Encode the maximum number of seconds that the regulation unit may run when
shutting the valve.

MANUAL START

This function allows spreading to start even if the machine is not moving forwards.
This function can be used, e.g. in corners when an area may be missed due to
tubes and pipes in the system needing to be filled with slurry.
The main slurry valve can be opened using the selected implement sensor, i.e. the
start/stop key, for the number of seconds encoded.