Operation, On screen indicators, System errors – TeeJet Sentry 6140 User Manual
Page 15: Operation 13, Sentry 6140 tip flow monitor
13
98-05306-ENUS R2
Sentry 6140 Tip Flow Monitor
operAtion
After the tips are balanced, the user can enter Operation mode. The system will monitor all the tips and their the flow rate if their respective boom
section is turned on. The flow rate of each tip must be within the percentage range (entered in the Setup mode). If any tip is outside this range,
an error will be generated, and the user will need to inspect the tip that is at fault. The LED on the Tip Sensor Interface
(H or I)
will also be
illuminated corresponding to the tip or tips that are at fault.
On Screen Indicators
Boom Sections
►Blue, spray shown – turned on
►Empty, no spray – turned off
►Red – a tip on that section has an error and needs to
be inspected.
Status Box
►Green Check Mark – shows all tips are operating normally
►Red flashing – an error occurred,
• Tip error – the Status Box will show the tip number(s) that is
at fault with the percentage off or “N/C” when the specified tip
is not connected.
• System error – the Status Box will show an error code
Buttons
►Reset button
– inactive unless an error occurs. It is then
enabled to run the system again after checking the tips.
►Next Error button
– only enabled if more than one error is
found when operating. It allows the user to cycle through the list
of tips that need to be checked.
Figure 25: Operation – All Tips OK
Figure 26: Operation – Tip Error
System errors
The errors that prevent the console from going into normal operation
are now displayed as error codes in the Status Box.
Error Codes:
• #1 - Number of tips or boom sections entered in setup mode does
not match number of tips or boom sections detected
• #2 - Terminator
(K or L)
not detected
• #3 - Boom Interface Module
(E)
not detected
• #4 - Lost communication with Tip Flow Monitor Interface (TFMI)
(B)
If any of these errors occur while in normal operation, the system will
beep 3 times to alert that an error has occurred.
Figure 27: Operation – System Error