Sentry 6140

Tip Flow Monitor

tip BALAnCe

Balancing the tips is required for the system to compare and

monitor individual tips. The system will scan all the tips to get the

flow rate. The flow rate of each tip must be within the tip balance

percentage range of the average flow rate in order to balance

successfully. If any tip is outside this range, an error will be generated,

and the user will need to inspect the tip.
NOTE: In order to maintain system accuracy, balancing the tips is

required anytime a tip is changed.

The console will not be able to detect small flow changes

until a tip balancing is completed successfully.

Tip Balance Percentage is OEM specified. Default balance

is +/-15%.

Figure 23: Tip Balance

Balance

Status Box

showing tip error

Boom Status

Next Error

Home

To check if the tips are balanced:
1. Machine must be spraying at normal operation parameters.
2. Press BALANCE button

on the Home Screen.

3. Press BALANCE button

to start the balance check. The

on-screen boom sections will flow on and off during this

check.

4. If an error occurs, the Status Box and boom section will flash red.

The Status Box show the tip or tips that are at fault including their

percentage of error or N/C for “not connected”. Inspect the tip(s)

noted on the Status Box. The LED on the Tip Sensor Interface

(H or I)

will also be illuminated corresponding to the tip or tips that

are at fault.
The NEXT ERROR button

is only enabled if more than one

error is found when balancing the tips.

5. After correcting the problem, press BALANCE button

to start

new balance check.

Figure 24: Tip Balance Process