Display brightness, Master sound, Tip alarm percentage – TeeJet Sentry 6140 User Manual
Page 12: Tip alarm delay, Tip flow monitor, Sentry 6140
10
www.teejet.com
Sentry 6140
Tip Flow Monitor
Display Brightness
Sets the brightness level of the display. Range is 5% to 100% in
5% increments.
1. Press the MINUS/PLUS buttons
to adjust the brightness.
2. Press
►NEXT PAGE button
to proceed to Master Sound.
►PREVIOUS PAGE button
to go back to Boom Section On/
Off Beep.
Figure 16: Display Brightness
Master Sound
Enable/disable console sound.
1. Press the UP/DOWN buttons
to toggle the sound on or off.
2. Press
►NEXT PAGE button
to proceed to Tip Alarm Percentage.
►PREVIOUS PAGE button
to go back to Display Brightness.
Figure 17: Master Sound
tip Alarm percentage
Sets the error reporting range for the tip sensors. If the flow
rate of an individual tip falls below, or rises above this range,
the console will generate an alarm. The value entered is the
percentage above and below the average flow that a tip must pass
to trigger an alarm. Range is 0% to 100%.
1. Press the MINUS/PLUS buttons
to adjust the percentage.
2. Press
►NEXT PAGE button
to proceed to Tip Alarm Delay.
►PREVIOUS PAGE button
to go back to Master Sound.
Figure 18: Tip Alarm Percentage
tip Alarm Delay
Sets the time the console will wait after an error has been
encountered before sounding a tip alarm. If the error is corrected
within this time, no alarm will sound or error will display on screen. The
delay value is selectable from 1 to 10 seconds.
1. Press the MINUS/PLUS buttons
to adjust the time.
2. Press
►NEXT PAGE button
to proceed to Number of Sections.
►PREVIOUS PAGE button
to go back to Tip Alarm
Percentage.
Figure 19: Tip Alarm Delay