beautypg.com

Display brightness, Master sound, Tip alarm percentage – TeeJet Sentry 6140 User Manual

Page 12: Tip alarm delay, Tip flow monitor, Sentry 6140

background image

10

www.teejet.com

Sentry 6140

Tip Flow Monitor

Display Brightness

Sets the brightness level of the display. Range is 5% to 100% in

5% increments.

1. Press the MINUS/PLUS buttons

to adjust the brightness.

2. Press

►NEXT PAGE button

to proceed to Master Sound.

►PREVIOUS PAGE button

to go back to Boom Section On/

Off Beep.

Figure 16: Display Brightness

Master Sound

Enable/disable console sound.

1. Press the UP/DOWN buttons

to toggle the sound on or off.

2. Press

►NEXT PAGE button

to proceed to Tip Alarm Percentage.

►PREVIOUS PAGE button

to go back to Display Brightness.

Figure 17: Master Sound

tip Alarm percentage

Sets the error reporting range for the tip sensors. If the flow

rate of an individual tip falls below, or rises above this range,

the console will generate an alarm. The value entered is the

percentage above and below the average flow that a tip must pass

to trigger an alarm. Range is 0% to 100%.
1. Press the MINUS/PLUS buttons

to adjust the percentage.

2. Press

►NEXT PAGE button

to proceed to Tip Alarm Delay.

►PREVIOUS PAGE button

to go back to Master Sound.

Figure 18: Tip Alarm Percentage

tip Alarm Delay

Sets the time the console will wait after an error has been

encountered before sounding a tip alarm. If the error is corrected

within this time, no alarm will sound or error will display on screen. The

delay value is selectable from 1 to 10 seconds.
1. Press the MINUS/PLUS buttons

to adjust the time.

2. Press

►NEXT PAGE button

to proceed to Number of Sections.

►PREVIOUS PAGE button

to go back to Tip Alarm

Percentage.

Figure 19: Tip Alarm Delay