3.3.4 Alarms

The Favor S features visual and audible alarms, to alert you when you are approach-

ing dangerous situations.
Potential danger situations during a dive, occurs when:

• the no-decompression dive turns into a decompression dive. One arrow

pointing upwards and the ascend warning CEILING/ASC TIME will appear

together with an audible alarm: three single beeps. (Fig. 3.13).

Immediate danger, happens when:

• the maximum allowed ascent rate, 10 m/min [33 ft/min], is exceeded. A

blinking SLOW warning will alternate with the depth display, and a

continuous beeping alarm is given. (Fig. 3.12).

• the ceiling depth is exceeded. A downward pointing arrow and a blinking

error warning Er will appear, and a continuous beeping alarm is given.

(Fig.3.16). You should immediately descend to or below the ceiling. The

dive computer will otherwise enter a permanent error mode in three minutes,

indicated by a non-blinking Er.

• the ceiling descends to 10 m [30 ft]. A blinking error warning Er appears.

You should immediately ascend to or below the ceiling.

• the ceiling descends to 12 m [39 ft]. A permanent error warning Er appears.

In this mode the instrument can only be used as a depth gauge and timer.

Fig. 3.12 ASCENT RATE INDICATOR

Pointer at position four: ascent rate is

more than 11 m/min [36 ft/min]. Blinking

SLOW displayed means that the ascent

rate 10 m/min [33 ft/min] has been

violated continuously. This is a caution to

slow down!

Fig. 3.13 DECOMPRESSION DIVE, BELOW THE CEILING ZONE

The minimum ascent time is 4 minutes. The upward pointing arrow tells you to ascend. The ceiling is at 3 m [10 ft].