Dive numbering shown during dive planning, 2 dive planning – SUUNTO FAVOR S User Manual
Page 24
24
NOTE: Temperature affects the battery voltage. If the dive computer is stored at
temperatures below freezing point, the low battery warning may be displayed even
though the battery has enough capacity in warmer conditions. Make sure that the low
battery warning disappears before diving.
3.2.2 Dive Planning
It is possible at any time on the surface to enter the DIVE PLANNING mode, simply
by touching the PLAN/ON and COM contacts. The display will rapidly cycle through
the no-decompression limits for various depths from 9 m [30 ft] to 45 m [150 ft] in 3 m
[10 ft] increments (Fig. 3.5). It takes about 45 seconds to run through the complete
cycle, after which the dive computer will automatically return to the READY display.
Higher personal/ altitude adjustment modes will shorten the no-decompression time
limits. These limits at different personal/ altitude adjustment mode selections are
shown in Tables 6.1 and 6.2 in Section 6.1, OPERATING PRINCIPLES.
DIVE NUMBERING SHOWN DURING
DIVE PLANNING
Several repetitive dives are considered to belong to the same repetitive dive series
when the dive computer has not deactivated itself. The first dive of the series will be
numbered as DIVE 1, the second as DIVE 2, the third as DIVE 3 etc. (Fig. 3.6). When
the surface time has been less than 10 minutes, the dives are considered to be the
same. The dive number will not change for the second part of such a dive and the dive
time will start where it left off.
Fig. 3.5 DIVE PLANNING
The no-decompression time limit at 30.0
m [100 ft] is 14 minutes in A1 mode.
Fig. 3.6 DIVE PLANNING
The no-decompression time limit at
30.0 m [100 ft] is decreased to 5 minutes in
A1 mode after the third dive of the series.
LOG
HIS
ALT
SET PLAN
R
A
T
E
A
S
C