Sterling Scale 825 User Manual
Page 8

_____________________________________________________________________________________________________________
Revision 4.4 Copyright ©2004Sterling Scale Co., Inc. March 2005
Web Site:
www.sterlingscale.com
E-mail: [email protected]
Name
Values
Description
ZT
0 Zero
tracking
disabled
(Zero Tracking)
0.2
Zero
tracking
at
± 0.2 graduations
0.6
Zero
tracking
at
± 0.6 graduations
1 Zero
tracking
at
±1 graduation
3
Zero tracking at
± 3 graduations
This scale will be re-zeroed within the chosen graduation
DA OFF
Digital averaging disabled
.
(Fast update – recommended for
applications
(Digital Average)
where speed is a prime consideration, such as filling
operations)
LOW
Digital averaging at low
(Norma setting for parts counting)
MED
Digital averaging at medium
(Normal weighing applications)
HI
Digital averaging at hi
(
Recommended for areas with heavy vibrations)
ZR
1.5
Zero
range
at
1.5
percent
of
full
scale
(Zero Range)
100
Zero range at 100 percent of full scale
U
LB.
Pounds
only
(Units)
KG
Kilograms
only
G
Grams
only
LB/KG
Pounds
to
Kilogram
conversion
LB/G
Pounds to Grams conversion
KG/G
Kilogram to Gram conversion
ALL
Pounds, Kilogram, Grams conversion counting operation
is disabled
MB
0
Motion band disable
(Not recommended for normal operations)
(Motion Band)
0.1
Motion band at 0.1 graduations
(Most sensitive setting counting)
0.2
Motion band at 0.2 graduations
(Counting and weighing with printer)
0.3
Motion band at 0.3 graduations
(Light vibrations and air movement
0.4
Motion
band
at
0.4
graduations
(Standard setting)
0.5
Motion
band
at
0.5
graduations
0.6
Motion
band
at
0.6
graduations
0.7
Motion
band
at
0.7
graduations
0.8
Motion
band
at
0.8
graduations
0.9
Motion
band
at
0.9
graduations
(Least sensitive)
1.0
Motion band at 1.0 graduations (
Least sensitive)
SM
OFF
Setpoint
Off
(Setpoint Mode)
CUT
Setpoints set for cutoff operations
COM
Setpoints set for comparator operations
SA
NO
Normally
open
(Setpoint Activation)
NC
Normally
closed
SD
QTY
Setpoints
operate
will
quantity
displayed
(Setpoint Data)
GRS
Setpoints
operate
with
gross
displayed
NET
Setpoints operate with net displayed
SS
F
Setpoints will activate even when the scale is in motion
(Setpoint Stable)
T
Setpoints will activate only when the scale is stable
PARAMETERS SETUP AND CALIBRATION