5 Installation

5.1

Fresh water system layout

5.2

Raw water system layout

Note

Use cold water only . Include shut-off valve in water line for maintenance purposes .

Notes

Use cold water only . Include shut-off valve in water line for maintenance purposes .
Use primary and secondary raw water filters .
Raw water pump MUST NOT be demand-type . Pump is controlled by flush switch .
Install vented loop as shown . It must be equipped with integral check valve that permits air into line to
prevent siphoning .

Dometic macerator toilets can operate with an
onboard pressurized freshwater system with a
minimum flow rate of 2 .0 gpm (7 .6 lpm) at the
toilet . Onboard fresh-water demand systems
include a water pump that automatically draws
water from a water storage tank when a valve
anywhere in the piping system is opened .

Dometic macerator toilets can flush on seawater but require a separate pump for this purpose . The
pump is activated by the signal from the toilet’s flush switch . If the raw water pump draws more
than 18 amps of current, a 12 or 24 V DC electrical relay must be installed .

Dometic 8100 series toilets are equipped with
an electrically operated water valve and an
in-line check valve to prevent contamination of
onboard potable supplies .

5

6

VENT

FITTING

SEACOCK

VENT

FILTER

DISCHARGE

PUMP

DECK

DISCHARGE

“FULL” LEVEL

PROBE (opt.)

MACERATOR

TOILET

MACERATOR

TOILET

FLUSH

SWITCH

PANEL

FLUSH

SWITCH

PANEL

0.5 in./13 mm

FRESH WATER

HOSE

0.5 in./13 mm

WATER HOSE

0.625 in./16 mm HOSE

1 in./25 mm HOSE

SEACOCK

TO SUCTION SIDE OF

RAW WATER PUMP

FINE WATER FILTER

(100 MESH)

SMALL ENGINE INTAKE STRAINER (COARSE)

WATER LINE

HOLDING TANK

(cut-away view)

VENTED LOOP/CHECK VALVE

Must be 8 in ./203 mm above water

line during all conditions of heel,

trim or load