Model No. Decoding

Example: EEDU400-6

• Model Designation

EEDU

• Size

400

• Series No.

-6

The Series No. which changes when the product line is re-certified (see

chart on page 3) is important in the selection of certain replacement parts.

Suffixes to the Model No.

2 = Two Stage Valve

H = High Altitude Orifices

MV = Electronic Modulation

S = Stainless Steel Heat Exchanger

De-Coding a Serial No.
Sample:

E AZJ 66 K8 N 12345 MV3

1 | 2 | 3 | 4 | 5 | 6 | 7

1 = Stainless steel heat exchanger (a standard

aluminized heat exchanger has no letter suffix)

2 = Date code (see page 3)

3 = Ignition code (Reference Form P-VALVES)

4 = Valve code (Reference Form P-VALVES)

5 = N is natural gas; L is propane

6 = Consecutive number

7 = Maxitrol system (optional)

Introduction and

Recertification Dates

Date of Manufacture - First Element of the Serial Number

Year

Jan

Feb

Mar

Apr

May

June

July

Aug

Sept

Oct

Nov

Dec

1981

AGA

AGB

AGC

AGD

AGE

AGF

AGG

AGH

AGI

AGJ

AGK

AGL

1982

AHA

AHB

AHC

AHD

AHE

AHF

AHG

AHH

AHI

AHJ

AHK

AHL

1983

AIA

AIB

AIC

AID

AIE

AIF

AIG

AIH

AII

AIJ

AIK

AIL

1984

AJA

AJB

AJC

AJD

AJE

AJF

AJG

AJH

AJI

AJJ

AJK

AJL

1985

AKA

AKB

AKC

AKD

AKE

AKF

AKG

AKH

AKI

AKJ

AKK

AKL

1986

ALA

ALB

ALC

ALD

ALE

ALF

ALG

ALH

ALI

ALJ

ALK

ALL

1987

AMA

AMB

AMC

AMD

AME

AMF

AMG

AMH

AMI

AMJ

AMK

AML

1988

ANA

ANB

ANC

AND

ANE

ANF

ANG

ANH

ANI

ANJ

ANK

ANL

1989

AOA

AOB

AOC

AOD

AOE

AOE

AOG

AOH

AOI

AOJ

AOK

AOL

1990

APA

APB

APC

APD

APE

APF

APG

APH

API

APJ

APK

APL

Example of a Rating

Plate

Key to Rating Plate

A = Standard

B = Model and Size

C = Date of Manufacturer

D = Serial No.

E = Volts/PH/Hz/Amps

F & G = Natural Gas or Propane

H & I = Altitude

J = Orifice Drill Size

K = Normal Input (altitude

adjusted)

L = Thermal Output (altitude

adjusted)

M = Minimum Input (altitude

adjusted)

N = Normal Manifold Pressure

O = Minimum Gas Supply

Pressure

P = Maximum Air Throughput

Q = Minimum Air Throughput

R = Normal Input (sea level)

S = Thermal Output (sea level)

T = Minimum Input (sea level)

The rating plate is located on the cover of the electrical junction box. Find the serial

number on the heater rating plate. See page 2 to decode the serial number and model

number.

REZNOR

MERCER, PA. USA 16137

MADE IN MEXICO

DUCT FURNACE

CATEGORY III

FOR INDUSTRIAL/COMMERCIAL USE ONLY

ANSI Z83.8 [ AA ] - [ A ] CSA 2.6 [ AA' ] - [ A' ] DUCT FURNACE

MODEL [ B ] [ C ]

SERIAL NO. [ D ]

[ E ] VOLTS [ E ] PH [ E ] HZ MAXIMUM TOTAL INPUT [ E ] AMPS

TYPE OF GAS: [ F ] [ G ]

ORIFICE SIZE [ J ] DRILL HAS BEEN FACTORY ADJUSTED

FOR USE AT [ H ] FEET [ I ] METERS OF ALTITUDE.

SEA

LEVEL

ALT.

AD-

JUSTED

NORMAL INPUT

[ R ] [ K ] BTU/

HR

OUTPUT CAPACITY

[ S ] [ L ] BTU/

HR.

MINIMUM INPUT(2,M,MV MODELS) [ T ] [ M ] BTU/HR.

NORMAL MANIFOLD PRESSURE

[ N ] IN.W.C.

MIN. PERMISSIBLE GAS SUPPLY PRESSURE

FOR PURPOSE OF INPUT ADJUSTMENT.

[ O ]

IN.W.C.

MAXIMUM THROUGHPUT [ P ] C.F.M.

MINIMUM THROUGHPUT [ Q ] CFM

CLEARANCES TO COMBUSTIBLE CONSTRUCTION: TOP- 6" , FLUE

CONNECTION-6", LEFT SIDE-12", RIGHT SIDE- 12", BOTTOM- 12"

THIS UNIT MAY BE INSTALLED ON NONCOMBUSTIBLE FLOORS.

THIS UNIT SHALL BE INSTALLED ON THE POSITIVE PRESSURE SIDE

OF THE AIR CIRCULATING BLOWER.

THIS UNIT MAY BE INSTALLED DOWNSTREAM FROM A REFRIGERATION

SYSTEM (USE DRAIN OPTION CS1).

FOR ALTERNATE INSTALLATIONS USE THE LATEST EDITIONS OF THE

APPROPRIATE STANDARD LISTED BELOW:

FOR AIRCRAFT HANGERS USE STANDARD ANSI/NFPA 409

FOR PARKING STRUCTURES USE STANDARD ANSI/NFPA 88A

FOR REPAIR GARAGES USE STANDARD ANSI/NFPA 88B

Certification

Series (see Model No. Decoding above)

Date

For installation in

the United States

Introduction (no series no.)

AGE (5/81)

3

AMI (9/87)

6

AUK (11/95)

For installation in

Canada

Introduction (no series no.)

AGE (5/81)

3

AMI (9/87)

5

AQK (11/91)

6

AUK (11/95)

NOTE: Manufacture

of Model HEEDU is

discontinued as of 6/2011.

This manual is related to the following products: