Wiring dia gram – Reznor Q6SD (3ph) Unit Installation Manual User Manual

Page 19

background image

19

Figure 11.Wiring Diagram for 460V Units

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

9

10

11

12

C

R

S

T2

T1

N

G

L

C

T3

T4

T5

1

NC

2

C

3

4

T

O

A

C

LINE

PO

WER

9

8

1

7

6

5

4

3

2

9

8

1

7

6

5

4

3

2

9

8

1

7

6

5

4

3

2

9

8

1

7

6

5

4

3

2

COMPRESSOR

COMPRESSOR

CAP

A

CIT

OR

DEFR

OST

SENSOR

REVERSING

V

A

LVE

SOLENOID

T

O

DISCHARGE

AIR SENSOR

ECONOMIZER

PLUG

ECONOMIZER JUMPER

9-WIRE HARNESS

3 AMP

FUSE

BLO

WER

RELA

Y

BLO

WER

MO

T

O

R

BLACK

BLACK

YE

YE

OR

CONT

A

C

T

O

R

TRANSFORMER

24V

480V

COM

Low

Voltage

Terminals

T2

DFT

TEST

C

Y

O

W2

R

E

DF1 DF2

T1
T2

C
Y

O

W2

R

DFT

E

DEFR

OST

BO

ARD

BLUE

ORANGE

FIELD WIRING

LEGEND:

LO

W V

O

LT

A

G

E

HIGH V

O

LT

A

G

E

BLAC

K

W1

CL

O

W

2

E

G

R

Y2

Y1

T2

T1

T3

CCH

L2

L1

L3

T2

T1

T3

13

46

2

5

BLA

CK

ORANGE

BLUE

WHITE

BLA

CK

BLA

C

K

BLA

CK

BLA

C

K

BLA

CK

BLA

CK

WHITE

HEA

TER

PLUG

JUMPER

PLUG

LO

W PRESSURE

SWITCH

(IF EQ

UIPPED)

HIGH

PRESSURE

SWITCH

RED

BLUE

BLA

C

K

GREEN

RED

YELLO

W

GRA

Y

ORANGE

BLUE

RED

WHITE

RED

YELLOW

YELLO

W

WHITE

460 V

olt

z

H

0

6

e

s

a

h

P

e

er

h

T

p

m

u

P

t

a

e

H

d

e

g

a

k

c

a

P

el

bi

tr

e

v

n

o

C

WIRING DIA

GRAM

NO

TES:

1.

Disconnect all po

wer bef

ore ser

vicing.

2.

For suppl

y connections use copper conductor

s onl

y

.

3.

If an

y of the original wire as supplied with the furnace

m

ust be replaced,

it m

ust be replaced with wiring

material ha

ving a temperature rating of at least 105°C.

4.

For suppl

y wire ampacities o

ver

current pr

otection,

see

unit rating plate

.

1.

Couper le courant a

v

ant de faire letretien.

2.

Emplo

y

ez uniquement des conducteur

s en cuivre

.

7110020

1009

DEFROST BO

ARD OPERA

TION:

1 CL

OSES DURING DEFROST

. RAITNG:

1 A MAXIMUM

2 OPENS DURING DEFROST

. 2 HP A

T

230

V

A

C MAXIMUM

3 CL

OSED

WHEN

“Y

” IS ENERGIZED

. OPEN

WHEN

“Y

” IS DEENERGIZED

.

PROVIDES

“OFF”

DELA

Y

TIME OF 5 MIN

WHEN

“Y

” IS DEENERGIZED

.

4

WITH DTF CL

OSED AND

“Y

” ENERGIZED

, C

OMPRESSOR RUN

TIME IS A

C

CUMLA

TED

.

OPENING OF DFT DURING DEFROST OR INTER

V

AL PERIOD RESET

S

THE INTER

V

AL

T

O

0.

NO

TE:

S

ee Installation

Instruc

tions f

o

r wiring

,

application,

and

Inf

ormation c

oncerning

acc

essor

y

Heat K

its and

other options

.

BR

O

W

N

RED

BR

O

W

N

ORANGE

YELLO

W

BLA

CK

BLA

CK

RED

RED

BLUE

GREEN

WHITE

YELLO

W

BLA

CK

BLUE

GREEN

GREEN

BR

O

W

N

GREEN

WHITE

WHITE

BLUE

BR

O

W

N

RED

BLA

CK

YELLO

W

RED

RED

BLA

CK

BLA

CK

(Replaces 7108610)

¢711002T¤