Reznor CK10 Option - Installation - Hanger Kit Installation - Unit Heaters User Manual
Optional hanger kits, Description/application/table of contents, Applies to
Form I-OPT-HK (Version A.1), Mfg #98346 (Rev 4), Page 1
Optional Hanger Kits
Option Installation Form RZ-NA I-OPT-HK
(Version A.1)
Obsoletes Form I-OPT-HK Version A
APPLIES TO:
Hanger Kit Options CK3,
CK7, CK8, CK9, CK10, CK19
HAZARD INTENSITY LEVELS
1. DANGER: Failure to comply will result in severe
personal injury or death and/or property damage.
2. WARNING: Failure to comply could result in severe
personal injury or death and/or property damage.
3. CAUTION: Failure to comply could result in minor
personal injury and/or property damage.
Description/Application/Table of Contents
Description, parts listing, and illustrated instructions are provided for each hanger kit. These kits are designed
only for the models and applications described below.
See the referenced heater installation manual for clear-
ances (top, sides, bottom, front, and rear), suspension dimensions, and weights. Suspension of the heater is the
responsibility of the installer.
WARNING: The instructions in this sheet are written for adding new suspension points or
preparing a heater for suspension prior to installation. If your heater is installed, for your
safety, turn off the gas and the electric before adding or changing suspension. Follow the
instructions on the heater to restart. Check for proper operation.
Other
Ce iling Bracket for Unit Heaters - Option CK22 is available for small sizes of Models UDAP and UDAS.
Hanger See Supplemental Installation Form RZ-NA I-UD-CS.
Kits
Infrared Models - Options CK11-CK18 are not included in this form. Options CK11-CK18 are hanging chain and
turnbuckle kits for tubular infrared heaters. For parts lists and instructions for hanger and turnbuckle kits, see Supple-
mental Installation Form RZ-NA I-VR-HK and/or RZ-NA I-VR/TRP/TR-TK. Hanging chain for infrared high intensity
heaters is Option UE1 or UE2. See Heater Installation Manual, Form RZ-NA I-RIH.
Option
Kit
Description
Use with
Models
Application
Page
Reference Heater Installation Manual
by Model
CK3
Swivel Connections
for 1" Pipe for 4-pt
Suspension
(H)EEDU Duct
Furnace
To adapt the duct furnace so that it may be
suspended from threaded 1" stationary
pipes.
2
EEDU and HEEDU - Form RZ-NA I-
EEDU
CK7
4-pt Suspension
Conversion
F
To add two hanger brackets for changing
from standard 2-pt suspension to 4-pt
suspension.
2-3 F - Form RZ-NA I-F/B
3-4 UDAP and UDAS - Form RZ-NA I-
UDA
F - Form RZ-NA I-F/B
CK9
4-pt Suspension
Conversion Plus
Swivel Connections
F
To add two hanger brackets to change from
standard 2-pt suspension to 4-pt
suspension and adapt the unit so that it
may be suspended from four threaded 1"
stationary pipes.
4
F - Form RZ-NA I-F/B
5-6 LDAP - Form RZ-NA I-LDAP
UDAP and UDAS - Form RZ-NA I-
UDA
UDBP and UDBS - Form RZ-NA I-
UDB
B and F - Form RZ-NA I-F/B
OH and OB - Form RZ-NA I-OH/OB
RA and RAD - Form RZ-NA I-
RA/RAD 140/235
RA and RAD - Form RZ-NA I-
RA/RAD 350/500
CK19
Alternate Suspension
Points providing
nearly equal loading
at four points
B
Suitable for units equipped with isolation
vibration suspension and or seismic pro-
tection with longer than 10" rod hangers.
Option CK19 changes the suspension
points and suspension dimensions.
7-8 B - Form RZ-NA I-F/B
CK8
Swivel Connections
for 2" pipe for 2-pt
Suspension
UDAP; UDAS; F To adapt a unit with 2-pt suspension so
that it may also be suspended from two
threaded stationary pipes.
CK10
Swivel Connectors
for 1" Pipe for 4-pt
Suspension
LDAP Packaged
Heaters; UDAP;
UDAS; UDBP;
UDBS; B; OH;
OB; RA; RAD;
and F with
optional 4-pt
suspension
To adapt a unit with 4-pt suspension so
that it may be suspended from four
threaded 1" stationary pipes.
- CK9 Option - Installation - Hanger Kit Installation - Unit Heaters CK8 Option - Installation - Hanger Kit Installation - Unit Heaters CK7 Option - Installation - Hanger Kit Installation - Unit Heaters CK19 Option - Installation - Hanger Kit Installation - Unit Heaters CK3 Option - Installation - Hanger Kit Installation - Unit Heaters