GS C1 n1 n2 n3 n4 n5 n6

[Function]

Setting the numbering counter mode (A)

[Code]

<1D>H<43>H<31>H

[Range]

0

n1, N2, N3, N4, N5, N6

255

[Outline]

This command sets the numbering (serial number counter) mode.

n1 + n2

×

256 (n1 = remainder, n2 = quotient)

: Counter default

n3 + n4

×

256 (n3 = remainder, n4 = quotient)

: Counter final value

n5

: Counter step value

n6

: I de nt i ca l count e r pr i nt c ount

(n1 + n2

×

256) < (n3 + n4

×

256)

: Count-up system

(n1 + n2

×

256) > (n3 + n4

×

256)

: Count-down system

(n1 + n2

×

256) = (n3 + n4

×

256) or n5 = 0 or n6 = 0 : Counter stop

[Default]

n1 + n2

×

256 = 1

n3 + n4

×

256 = 65535

n5 = 1

n6 = 1

[See Also]

GS C0, GS C2, GS c, GS C ;

[Sample Program]

LPRINT CHR$ (&H1D) ; "C0" ;

* CNT

LPRINT CHR$ (3) ; CHR$ (0) ;

FOR I=1 TO 6

LPRINT CHR$ (&H1D) ; "C1" ;

LPRINT CHR$ (&HID) ; "c" ;

LPRINT CHR$ (50) ; CHR$ (0) ;

NEXT I

LPRINT CHR$ (0) ; CHR$ (0) ;

LPRINT CHR$ (&HA) ;

LPRINT CHR$ (5) ; CHR$ (2) ;

RETURN

GOSUB * CNT

LPRINT CHR$ (&H1D) ; "C2" ;

LPRINT CHR$ (5) ; CHR$ (0) ;

GOSUB * CNT

END

[Print Result]

When setting a count-down range = 0 to 50, step value

= 5, repeat count = 2, and start value = 5 to print a

counter value.

When setting a count-down range = 0 to 50, step value

= 5, repeat count = 1, and start value = 50 to print a

counter value. (The repeat count is cleared)