beautypg.com

Power connector – Citizen Systems CBM-270 User Manual

Page 41

background image

CBM-270 User’s Manual

8.

POWER CONNECTOR

This connector is to supply the power from the special AC adapter(27AD).

Connector Schematic

No.

Function

1
2

7.2V

GND

1

2

Jack used

: HEC0470-01-640 (HOSHIDEN) or its equivalent

Applicable plug

: JXP series type A (I.D.: 2.45 mm, O.D.: 5.5 mm) (HOSHIDEN) or its equivalent

CAUTION:

1) Be sure to use the specified AC adapter. Use of any other power source could cause trouble to or break the

printer.

2)

Do not connect the power source with different polarity.

3)

After using the printer or when not using it for a long period of time, be sure to unplug the AC

adapter from a plug socket for your safety.

Inner terminal

: Minus pole (GND)

Outer terminal

: Plus pole