Serial interface – Citizen Systems CBM-270 User Manual
Page 38
CBM-270 User’s Manual
7.
SERIAL INTERFACE
7.1
Specifications
(1) Synchronous system
: Asynchronous
(2) Baud rate
: 1,200, 2,400, 4,800, 9,600, 19,200 bps (Selected by the user)
(3) 1-word configuration
Start bits
: 1 bit
Data bits
: 8 bits or 7 bits (Setting upon shipment)
Parity bits
: Odd, even, or no parity (Selected by the user)
Stop bits
: 1 bit or more
(4) Signal polarity
RS-232C
•
Mark
= Logic "1" (-3
∼
-12 V)
•
Space
= Logic "0" (+3
∼
+12 V)
(5) Received data (RXD signal)
•
Mark
= 1
•
Space
= 0
(6) Reception control (DTR signal)
•
Mark
:
Data not transferable
•
Space
:
Data transferable
(7) Transmission control (TXD signal)
•
DC1 code(11H) X-ON
:
Data receivable
•
DC3 code(13H) X-OFF
:
Data not receivable
7.2
Connector's Pin Configuration
No.
Signal Name
Input/Output
Function
1
FG
Frame Ground
7
GND
Signal Ground
3
RXD
Input
Received Data
20
DTR
Output
Printer BUSY Signal
2
TXD
Output
Transmitted Data
6
DSR
Input
Data Set Ready
[Note] 1. The RS-232C signals are based on the EIA RS-232C.
2. The received data should be always maintained in the Mark status when no data is being
transferred.
Applicable connectors (D-Sub connectors)
Printer side
: 17LE-13250 (Anphenol) or its equivalent
Cable side
: 17JE-23250 (Anphenol) or its equivalent
7.3