beautypg.com

Dip switch setting – Citizen Systems CBM-270 User Manual

Page 32

background image

CBM-270 User’s Manual

5.

DIP SWITCH SETTING

5.1

Location of DIP Switch

1. Turn off the power.

2.

Detach the printer cover, and take out the paper roll. (The switch is found under the paper roll.)

3. There are 2 switches (8-pole and 4-pole) for the serial interface, and 1 switch (8-pole) for the parallel

interface.

5.2

DIP Switch Function

DS1

No.

Function

ON

OFF

Upon Shipment

1

PNE selection

Enabled

Disabled

ON

2

CR switching

LF operation

Ignored

OFF

3

ON

4

Print density

See Table 1

OFF

5

Paper selection

Label paper

Thermal paper

OFF

6

Auto-loading

Enabled

Disabled

ON

7

DTR/DSR, XON/XOFF

XON/XOFF

DTR/DSR

OFF

8

Kanji code selection

S-JIS

JIS

OFF

DS1-7: Enabled only for the serial interface. Disabled for the parallel one.

DS2 (For Serial Interface Only)

No.

Function

ON

OFF

Upon Shipment

1

OFF

2

OFF

3

OFF

4

Baud rate and parity
setting

See Table 2

OFF

Light

Standard

Slitly Dark

Dark

DS1-3

OFF

ON

OFF

ON

DS1-4

OFF

OFF

ON

ON

DS2-4

DS2-3

DS2-2

DS2-1

Parity

Baud Rate

OFF

OFF

OFF

OFF

None

9,600 bps

OFF

OFF

OFF

ON

None

1,200

OFF

OFF

ON

OFF

None

2,400

OFF

OFF

ON

ON

None

4,800

OFF

ON

OFF

OFF

None

9,600

OFF

ON

OFF

ON

None

19,200

OFF

ON

ON

OFF

Odd

1,200

OFF

ON

ON

ON

Odd

2,400

ON

OFF

OFF

OFF

Odd

4,800

ON

OFF

OFF

ON

Odd

9,600

ON

OFF

ON

OFF

Odd

19,200

ON

OFF

ON

ON

Even

1,200

ON

ON

OFF

OFF

Even

2,400

ON

ON

OFF

ON

Even

4,800

ON

ON

ON

OFF

Even

9,600

ON

ON

ON

ON

Even

19,200

5.3

Jumper Wire Function

The jumper wires have been set at shipment. The following lists the basic settings at shipment. Check the

Table 2

Table 1