Table 1A—Physical Data

UNIT SIZE

50JS018

50JS024

50JS030

50JS036

50JS042

50JS048

50JS060

NOMINAL CAPACITY (ton)

1-1/2

2

2-1/2

2-1/2

3-1/2

4

5

OPERATING WEIGHT (lb)

283

289

287

291

323

353

418

COMPRESSOR QUANTITY

1

TYPE

RECIPROCATING COMPRESSOR

SCROLL COMPRESSOR

REFRIGERANT

R-22

REFRIGERANT METERING DEVICE

Accurater ®

Refrigerant (R-22) Quantity (lb.)

5.6

5.2

5.8

7.1

7.6

7.8

8.6

ORIFICE ID (in.)

0.053

0.061

0.068

0.078

0.078

0.088

0.093

ORIFICE OD (in.)

0.040

0.049

[email protected]

[email protected]

[email protected]

[email protected]

[email protected]

OUTDOOR COIL

Rows...Fins/in.

Face Area (sq ft)

1....17

10.2

1....17

12.0

1....17

12.0

2....17

10.3

2....17

10.3

2....17

11.6

2....17

11.6

OUTDOOR FAN

Nominal Airflow (CFM)

Diameter

Motor HP (RPM)

2400

22

1/8 (825)

2400

22

1/8 (825)

2400

22

1/8 (825)

2800

22

1/4 (1100)

2400

22

1/8 (825)

3300

22

1/4 (1100)

3300

22

1/4 (1100)

INDOOR COIL

Rows...Fins/in.

Face Area (Sq Ft)

2....15

3.7

2....15

3.7

3....15

3.7

3....15

3.7

4....15

3.7

3....15

4.7

4....15

4.7

INDOOR BLOWER

Nominal Airflow (CFM)

Size (in.)

Motor (HP)

700

10x10

1/8

800

10x10

1/4

1000

11x10

1/4

1200

11x10

1/2

1250

11x10

3/4

1600

11x10

3/4

2000

11x10

1

RETURN-AIR FILTERS (in.)

Throwaway

20x20x1

20x20x1

20x20x1

20x24x1

24x30x1

24x30x1

24x30x1

Table 1B—Physical Data

UNIT SIZE

50JX024

50JX030

50JX036

50JX042

50JX048

50JX060

NOMINAL CAPACITY (ton)

2

2 1/2

3

3-1/2

4

5

OPERATING WEIGHT (lb)

299

320

328

350

355

420

COMPRESSOR QUANTITY

1

TYPE

SCROLL COMPRESSOR

REFRIGERANT

R-22

REFRIGERANT METERING DEVICE

Accurater ®

Refrigerant (R-22) Quantity (lb.)

5.5

6.4

7.0

10.8

10.4

12.3

ORIFICE ID (in.)

0.065

0.073

0.076

0.080

0.088

0.0.93

ORIFICE OD (in.)

0.055

0.065

0.067

[email protected]

[email protected]

[email protected]

OUTDOOR COIL

Rows...Fins/in.

Face Area (sq ft)

1...17

14.6

2...17

10.9

2...17

10.9

2...17

14.4

2...17

14.4

2...17

16.4

OUTDOOR FAN

Nominal Airflow (CFM)

Diameter

Motor HP (RPM)

2350

22

1/8 (825)

2350

22

1/8 (825)

2800

22

1/4 (1100)

2800

22

1/8 (825)

3300

22

1/4 (1100)

3300

22

1/4 (1100)

INDOOR COIL

Rows...Fins/in.

Face Area (Sq Ft)

3...15

3.7

3...15

3.7

4...15

3.7

4..15

4.7

4...15

4.7

4...15

5.7

INDOOR BLOWER

Nominal Airflow (CFM)

Size (in.)

Motor (HP)

800

10x10

1/4

1000

11x10

1/4

1200

11x10

1/2

1400

11x10

3/4

1600

11x10

3/4

2000

11x10

1

RETURN-AIR FILTERS (in.)

Throwaway

20x20x1

20x20x1

20x24x1

24x30x1

24x30x1

24x30x1

NOTE: Air filter pressure drop for non-standard filters must not exceed 0.08 in. wg.

Table 2A—Minimum Airflow for Reliable Electric Heater Operation (Cfm)

SIZE

50JS018

50JS024

50JS030

50JS036

50JS042

50JS048

50JS060

AIRFLOW (CFM)

650

800

1000*

1200

1400

1600

2000

Table 2B—Minimum Airflow for Reliable Electric Heater Operation (Cfm)

SIZE

50JX024

50JX030

50JX036

50JX042

50JX048

50JX060

AIRFLOW (CFM)

800

1000*

1200

1400

1600

2000

* The 030 size models must be run on medium or high speed when used in conjunction with 15 Kw electric heat accessory.

7