5.6. System Settings
5.6.1. Calibrating Deadzones
Tip: Performing an Automatic retune will set the Deadzone and Gain Values
The Deadzone Value relates to the smallest amount of boom movement the valve can produce.
1. Ensure the sprayer is over bare level soil or gravel. The sprayer should be at operating temperature
and RPM.
2. Navigate to: Run Screen-> Settings-> Next-> Next-> Setup-> Valves.
3. Select the boom function. Press the "Deadzone" button.
4. Press and hold the manual “M” button.
5. Hold until the boom stops moving and the reading stabilizes.
6. The reported distance should be 1-2 inches (2-5cm). Adjust the Deadzone until the distance is within
1-2 inches (2-5cm).
5.6.2. Gains
The Gain value relates to the maximum speed of the boom.
1. The Gain calibration is dependent on the Deadzone value. Before calibrating the Gain, the Deadzone
value must be correctly calibrated for the same channel.
2. Ensure the sprayer is over bare level soil or gravel. The sprayer should be at operating temperature
and RPM.
3. Navigate to: Run Screen-> Settings-> Next-> Next-> Setup-> Valves.