21
4.7 H
YDRAULIC
I
NSTALLATION
WARNING!
The hydraulic system creates very high 
pressure. Before disconnecting any 
hydraulic lines ensure all pressure has 
been bled from the system. When 
changing the boom hydraulic hoses leave 
the booms in TRANSPORT POSITION. 
IMPORTANT:
Component failure due to oil 
contamination is not covered under the 
UC4+ Spray Height Control system 
warranty. It is recommended that a 
qualified technician does the hydraulic 
installation. 
1. Refer to Figure 22. On a clean surface
remove the plastic plugs from the “A”, “B”, 
“P”, and “T” ports of the NORAC hydraulic 
valve (V01). Install the 6MB-4MBSPP fittings 
(F02) on the “P” and “T” ports and tighten 
to 18 ft-lbs. 
2. Install the orifices (F01) into the “B” ports
with the notch facing outward as shown 
in Figure 23. An O-ring pick can be used to 
ease installing the orifices into their 
locations.  
3. Install the 6MB-4MBSP fittings (F02) into the
“B” ports and tighten to 18 ft-lbs.
4. Install the 6MBP plugs (F03) into the “A”
ports and tighten to 18 ft-lbs.
Figure 22: UC4+ Valve Block Ports
Figure 23: Valve Block Port Assembly