beautypg.com

7 hydraulic installation – NORAC UC4+BC+HD4 Part 1 User Manual

Page 25

background image

21

4.7 H

YDRAULIC

I

NSTALLATION

WARNING!

The hydraulic system creates very high
pressure. Before disconnecting any
hydraulic lines ensure all pressure has
been bled from the system. When
changing the boom hydraulic hoses leave
the booms in TRANSPORT POSITION.

IMPORTANT:

Component failure due to oil
contamination is not covered under the
UC4+ Spray Height Control system
warranty. It is recommended that a
qualified technician does the hydraulic
installation.

1. Refer to Figure 22. On a clean surface

remove the plastic plugs from the “A”, “B”,
“P”, and “T” ports of the NORAC hydraulic
valve (V01). Install the 6MB-4MBSPP fittings
(F02) on the “P” and “T” ports and tighten
to 18 ft-lbs.

2. Install the orifices (F01) into the “B” ports

with the notch facing outward as shown
in Figure 23. An O-ring pick can be used to
ease installing the orifices into their
locations.

3. Install the 6MB-4MBSP fittings (F02) into the

“B” ports and tighten to 18 ft-lbs.

4. Install the 6MBP plugs (F03) into the “A”

ports and tighten to 18 ft-lbs.

Figure 22: UC4+ Valve Block Ports

Figure 23: Valve Block Port Assembly