6613_OMU_2+2S_URT_V1_00 Firmware Description Document

UG_6613_060

40

Rev. 1.1

7 Address Content Summary

If the color shading is the same, the information in the table cells is the same between narrowband and
wideband measurements. Note that Outlet 1 = channel A and Outlet 2 = channel B.

Table 6: MPU Output Summary Chart

Outlet 1

Address

Wideband

Common Data

20

Delta Temp

21

Line Frequency

22

Alarm Status

23

Over Current Event Count

24

Under Voltage Event Count

25

Over Voltage Event Count

26

Volts

Common, Outlet 1
Specific Data

27

Watts (A)

28

Energy (A)

29

Cost (A)

Tier 1, Outlet 1 Specific
Data

2A

Current (A)

2B

VAR (A)

2C

VA (A)

2D

Power Factor (A)

2E

Phase (A)

2F

(Reserved for Future)

Tier 2, Outlet 1 Specific
Min/Max Data

30

Vrms Min

31

Vrms Max

32

Watts Min (A)

33

Watts Max (A)

34

Current Min (A)

35

Current Max (A)

36

VAR Min (A)

37

VAR Max (A)

38

VA Min (A)

39

VA Max (A)

3A

Power Factor Min (A)

3B

Power Factor Max (A)

3C

Phase Min (A)

3D

Phase Max(A)

3E

(Reserved for Future)

3F

(Reserved for Future)