6613_OMU_2+2S_URT_V1_00 Firmware Description Document

Rev. 1.1

13

4.5.1.2 CALW Command

The CALW command calibrates the temperature, voltage, and power (instead of the current).

To calibrate channel 1, enter the following:

>CALW or CALW1

The response is:

TCal OK
VCal OK:
WCal 1 OK:
>

To calibrate channel 2, enter the CAL2 command:

>CALW2

The response is:

TCal OK
VCal OK:
WCal 2 OK:
>

The device calibrates the temperature, the voltage, and the power and save all values to flash.

The CALW3 command calibrates both channel 1 and channel 2.

The complete calibration commands are summarized in the following table:

Complete Calibration Commands

Description:

Calibrates the IC.

Usage:

CAL

Calibrates temperature, then voltage,
and finally current for the given channel.
CAL1 = Calibrates channel 1
CAL2 = Calibrates channel 2
CAL3 = Calibrates channel 1 and 2

CALW

Calibrates temperature, then voltage,
and finally power for the given channel.
CALW1 = Calibrates channel 1
CALW2 = Calibrates channel 2
CALW3 = Calibrates channel 1 and 2