6613_PSU_1+1S_URT_V1_00 Firmware Description Document

UG_6613_040

24

Rev. 1.0

MPU

Parameter

Location

(hex)

LSB

Default

Comment

Example

Cost/kWh

AA

mUnits

+0.150

Cost per kWh (kilowatt hour) in

milliunits.

If the cost per kWh is to be

10 units:

)AD=+10.000

Units of Cost

AB

N/A

USD

4-byte string describing unit of

cost

(e.g. USD, EURO etc.). There

must be 4 characters. If entering

US dollars, USD, there needs to

be a space after the D to make it a

four character string.

To enter US Dollars:

)AB=”USD “

To enter Euros:

)AB=”EURO”

Reserved

A0 - BC

0

Reserved

Reserved

Additional

Status

BD

1

Bit 0 – Reserved.

Bit 1 – WPULSE Disable.

Bit 2 – VCal Failure.

Bit 3 – ICal1 Failure.

Bit 4 – WCal1 Failure.

Unused

BE

Tolerance on

Phase

BF

0.001°

0.100°

Measured value to fall within this

set tolerance of the target value

(Calibration Current entry) for the

calibration to be complete.

If the tolerance to the target

phase is desired to be more

coarse, to within 0.5°, the

user can enter the

following:

>)BF=+0.500

Reserved

C0

0

Reserved

Reserved

Calibration

Voltage

C1

mVrms

+120.000

Target line voltage (rms) used for

calibration.

If the target line voltage for

calibration is 220V, enter

the following:

>)C1=+220