6613_PSU_1+1S_URT_V1_00 Firmware Description Document
UG_6613_040
18
Rev. 1.0
The commands that follow are included for reference only.
6.7 CE Control Commands
The most pertinent command is the CE enable command, CEn. It is mainly used to turn the CE on or off.
The CE is normally enabled but in order to update the CE data entry to flash, the CE must first be turned
off using the CE0 command.
6.7.1 Disable CE Command
The CE can be disabled by using the following command:
>CE0
6.7.2 Turn On CE Command
The CE can be enabled by following command:
>CE1
Additional examples of CE Control Commands are provided in the following table:
C
Compute Engine Control
Description:
Allows the user to enable and configure the compute engine.
Usage:
C {option} {argument}
Command
Combinations:
CEn
Compute Engine Enable (1
Enable,
0
Disable)
CTn
Select input n for TMUX output pin. Enter n in hex
notation.
CREn
RTM output control (1
Enable, 0 Disable)
CRSa.b.c.d
Selects CE addresses for RTM output. (maximum
of four).
Examples:
CE0
Disables the CE.
CE1
Enables the CE.
CT1E
Selects the CE_BUSY signal for the TMUX output
pin.