8 Configuration Parameter Entry

8.1 MPU Parameters

Table 3 lists the MPU parameters configurable by the 6613_PSU_1+1S_URT_v1_00 Firmware.

Table 3: MPU Parameters

MPU

Parameter

Location

(hex)

LSB

Default

Comment

Example

VMAX A

A0

mVrms

+471.500

External rms voltage

corresponding to 250 mVpk at the

VA input of the 78M6613. It must
be set high enough to account for

overvoltages. Usually set to

471.500 V (471.500d).

If only using a 120V

system, the user can set

VMAX A to about 2x the

maximum voltage for added

resolution. Set VMAX A to

270V:

)A0=+270.000

Starting IA

A1

mArms

+0.007

Minimum current value to be

measured on the IA input.

Currents below this value will be
ignored. Also known as CREEP

IA.

Default setting is 7 mA. If

start current on channel A

desired is 10 mA:

)A1=+0.010

IMAX A

A2

mArms

+52.000

External rms current

corresponding to 250 mVpk at the

IA input of the 78M6613.

The default is set to 52

Amps for overhead. For

added margin, in a system
using current shunts IMAX

could be changed as

follows:

IMAX= (Vpk/

√2)/R

shunt

For a 4 m

Ω current shunt

IMAX=44.19 Amps

To set IMAX A:

)A2=+44.190

Unused

A3 - A5

Unused

Temperature

Nominal

A6

+0

Temp_raw_x reading at 22 °C.
Needed to enable temperature

compensation.

Temp _raw_x is obtained

from the CE:

]71?

This value is then entered

here:

)A6=+value in decimal

Also, the command:

>CLT

Will do the same as the

steps above.

Reserved

A7

Reserved

PPMC

A8

ppm/°C

-668

ppm per °C.

Do not change the default

setting.

PPMC

2

A9

ppm/°C

2

-341

ADC temperature compensation

ppm per °C

2

.

Do not change the default

setting.