Longshine LCS-8156C1 User Manual
Page 5

AT Commands for CX930xx Modem Reference Manual
102752B
Conexant
v
&S - DSR Override ............................................................................................................................... 3-26
+IPR - Fixed DTE Rate .......................................................................................................................... 3-27
+IFC - DTE-Modem Local Flow Control ................................................................................................ 3-28
+IBC – In Band Commands .................................................................................................................. 3-29
3.2.3
Call Control................................................................................................................................................... 3-33
D - Dial.................................................................................................................................................. 3-33
T - Set Tone Dial Default....................................................................................................................... 3-35
P - Set Pulse Dial Default...................................................................................................................... 3-35
A - Answer ............................................................................................................................................ 3-35
H - Disconnect (Hang-Up) .................................................................................................................... 3-36
O - Return to On-Line Data Mode......................................................................................................... 3-37
L - Speaker Volume .............................................................................................................................. 3-38
M - Speaker Control ............................................................................................................................. 3-38
&G - Select Guard Tone........................................................................................................................ 3-39
&P - Select Pulse Dial Make/Break Ratio.............................................................................................. 3-39
&V - Display Current Configuration and Stored Profiles ...................................................................... 3-40
&V1 - Display Last Connection Statistics ............................................................................................. 3-41
\V - Single Line Connect Message Enabl .............................................................................................. 3-42
%L - Report Line Signal Level.............................................................................................................. 3-43
%Q - Report Line Signal Quality........................................................................................................... 3-43
*B - Display Blacklisted Numbers ........................................................................................................ 3-43
*D - Display Delayed Numbers............................................................................................................. 3-44
–SLP= - Set Low Power Mode ............................................................................................................. 3-45
–STE= - Set Telephony Extension......................................................................................................... 3-46
-TRV – Tip & Ring Voltage ................................................................................................................... 3-51
-TTE - Threshold Adjustments for Telephony Extension ...................................................................... 3-52
3.2.4
Modulation Control Commands ................................................................................................................... 3-53
+MS - Modulation Selection ................................................................................................................. 3-53
+MR - Modulation Reporting Control ................................................................................................... 3-55
%E - Enable/Disable Line Quality Monitor and Auto-Retrain or Fallback/Fall Forward ......................... 3-57
B - CCITT or Bell ................................................................................................................................... 3-58
3.2.5
Error Control Commands ............................................................................................................................. 3-59
+ES - Error Control and Synchronous Mode Selection ........................................................................ 3-59
+EB - Break Handling in Error Control Operation ................................................................................. 3-61
+ESR - Selective Repeat ....................................................................................................................... 3-61
+EFCS - 32-bit Frame Check Sequence ................................................................................................ 3-62
+ER - Error Control Reporting .............................................................................................................. 3-63
+ETBM - Call Termination Buffer Management .................................................................................... 3-65
\B - Transmit Break to Remote ............................................................................................................. 3-66
\K - Break Control ................................................................................................................................. 3-67
3.2.6
Data Compression Commands..................................................................................................................... 3-69
+DS - Data Compression ...................................................................................................................... 3-69
+DS44 - V.44 Compression Select ....................................................................................................... 3-70
+DR - Data Compression Reporting ..................................................................................................... 3-71
%C - Enable/Disable Data Compression............................................................................................... 3-73