S86 - call failure reason code – Longshine LCS-8156C1 User Manual
Page 134
AT Commands for CX930xx Modem Reference Manual
3-110
Conexant
102752B
S86 - Call Failure Reason Code
When the modem issues a NO CARRIER result code, a value is written to S86 Register
to help determine the reason for the failed connection. S86 records the first event that
contributes to a NO CARRIER message. The code definitions are:
Range: 0-26
Default: 21
S86=0
Normal hangup, no error occurred.
S86=1 Reserved.
S86=2 Reserved.
S86=3
Call Waiting caused disconnect.
S86=4
Physical carrier loss.
S86=5
No error correction at the other end.
S86=6
No response to feature negotiation.
S86=7
This modem is async only; the other modem is sync only.
S86=8
No framing technique in common.
S86=9
No protocol in common.
S86=10
Bad response to feature negotiation.
S86=11
No sync information from the remote modem.
S86=12
Normal hangup initiated by the remote modem.
S86=13
Retransmission limit reached.
S86=14 Protocol
violation
occurred.
S86=15 Lost
DTR.
S86=16 Received
GSTN
cleardown.
S86=17 Inactivity
timeout.
S86=18
Speed not supported.
S86=19
Long space disconnect.
S86=20
Key abort disconnect.
S86=21
Clears previous disconnect reason.
S86=22 No
connection
established.
S86=23
Disconnect after three retrains.
S86=24
Call Waiting tone detected.
S86=25
Extension pickup detected.
S86=26 Remote
hangup
detected.