Reporting current or selected values, Reporting supported range of parameter values, Vcid - caller id (cid) – Longshine LCS-8156C1 User Manual
Page 27: Syntax, Defined values
AT Commands for CX930xx Modem Reference Manual
102752B
Conexant
3-3
Reporting Current or Selected Values
Command: +FCLASS?
Response:
Example:
0
For the default setting.
Reporting Supported Range of Parameter Values
Command: +FCLASS=?
Response: (
range)
Example:
0, 1, 1.0, 8
+VCID - Caller ID (CID)
This command controls the reporting and presentation of data associated with the Caller
ID services in the Incoming Call Line ID (ICLID) data format for the next call.
Syntax
+VCID=
Defined Values
Decimal number corresponding to the selected option.
0
Disable Caller ID reporting. (Default.)
1
Enables Caller ID with formatted presentation to
the DTE. The modem presents the data items in a
are date, time, name, and caller code (telephone
number),
2
Enables Caller ID with unformatted presentation
to the DTE.
Reporting Current or Selected Values
Command: +VCID?
Response:
Example:
0
For the default setting.
Reporting Supported Range of Parameter Values
Command: +VCID=?
Response: (
range)
Example: (0-2)