Troubleshooting Chart
Problem
Probable Cause
Corrective Action
System will not turn on and
on/off indicator light does not
illuminate
Coach ignition not in RUN
position
Turn ignition to RUN position
Parking brake not set
Set parking brake
Controls have been on for more
than four minutes and have
timed out
Turn ignition off and then back on
Control pad turns on but turns
off when leg button is pushed
Low voltage on battery
Start coach to charge battery
Control pad turns on, coach will
not auto-level, jacks down light
is on, jacks are retracted
Low fluid level
Check fluid level in reservoir. If fluid is low,
add fluid to FILL TO HERE line on reservoir.
If JACKS DOWN light remains on call
Lippert Service.
Jacks will not extend to ground,
pump is running
Little to no fluid in reservoir
Fill reservoir with DEXRON III ATF
Leg valve is inoperative
Clean, repair or replace
Electronic signal is lost
between control leg valves
Trace wires for voltage drop or loss
of signal. Repair or replace necessary
wires or replace control pad.
Any one or two jacks will not
retract
Hose damaged or
unconnected
Replace with new hose or reconnect
hose
Return valve inoperative
Replace inoperative return valve
Electronic signal is lost
between control and
solenoid
Attempt to retract jacks in manual
mode. If successful, replace control
pad. If not, test for voltage drop
between control pad and leg valve.
Repair bad wiring or replace defective
board or valve.
"Jacks Down" LED does not go
out when all jacks are retracted
Low fluid level
Fill reservoir to proper level with ATF
Retract pressure switch
inoperable
Check connection or replace
Alarm sounds and "Jacks
Down" LED starts flashing
while traveling, jacks are fully
retracted
Low fluid level
Fill reservoir to proper level with ATF
Retract pressure switch
inoperable
Check connection or replace
Jack bleeds down after being
retracted
Manual override valve open
Close override
Control panel powers up; "Low
Voltage" LED flashes
Engine not running
Start coach engine
"Low Voltage" LED is solid
Charging system faulty
Turn key OFF then, back ON again
to reset. Check power and ground
connections on battery, alternator and
chassis.
No Power to control panel
Tripped circuit breaker
Reset circuit breaker
Ignition not on
Turn ignition on