KERN & SOHN VFB 2T-3 User Manual
Page 27

27
VFB-BA-e-1310
8.5
Weighing with tolerance range
You can set an upper or lower limit when weighing with tolerance range and thus
ensure that the weighed load remains exactly within the set limits.
During tolerance controls such as dispensing, portioning or sorting the unit will
indicate whether a value exceeds or falls short of limits with an optical [ok] as well as
an audio signal according to the setting in the menu block “
“; see chapter
9.2.
Selectable mode
Description
bP 1
Acoustic signal turned off
bP 2
If load is within tolerance range, [ok] will be displayed
and audio signal will be sounded.
bP 3
If the load is beyond the tolerance range [ok] will be
shown and the audio signal will sound.
1. Call up menu
In weighing mode press
und
at the same time
and the first menu block
will appear.
2. Set limit values
Keep on pressing
until the display used for entering
the lower limit
SET LO
appears.
Press
, the current setting will be displayed.
Press the navigation buttons (see chap. 5.10.1) to enter the
lower limit value, the active digit is flashing.
(example)
Confirm input by
.
Select
SET HI
by pressing
.