Kenton Pro-SOLO MkII User Manual
Page 18

18
Address Function Range
Notes
(
see end
)
01h
Receive chan
0 - 15
{ 1 }
02h
trig / retrig
0 - 1
03h
note priority
0 - 2
04h
pitchbend range
0 - 24
05h
portamento cont #
253 - 0 - 119
{ 3 }
06h
portamento time / rate 0 - 127
07h
portamento type
0 – 1
0=fixed rate / 1= fixed time
08h
LFO to CV depth controller # 252 - 0 - 119
{ 4 }
09h
LFO to CV min val
0 - 127
0Ah
LFO to CV max val
0 - 127
0Bh
LFO to CV reset val
0 - 127
0Ch
coarse tune / transpose
232 > 0 > 24
{ 2 }
0Dh
fine tune val
129 > 0 > 127
129>0 = -ve
0Eh
scale val
129 > 0 > 127
129>0 = -ve
0Fh
v/o or hzv or 1.2v select
0 - 2
10h
gate select
0 - 7
5 modes used
14h
Aux1 Cont #
239 > 0 > 119
{ 6 }
15h
Aux1 min val
0 - 127
16h
Aux1 max val
0 - 127
17h
Aux1 reset val
0 - 127
18h
Key scale to Aux
0 - 127
19h
LFO to Aux1 cont #
252 - 0 - 119
{ 4 }
1Ah
LFO to Aux1 min val
0 - 127
1Bh
LFO to Aux1 max val
0 - 127
1Ch
LFO to Aux1 reset value
0 - 127
1Eh
Lfo speed
0 - 127
1Fh
Lfo waveshape
0 - 8
{ 7 }
20h
Lfo MIDI sync
0 - 96
{ 8 }
21h
Lfo sync start point
0 - 255
22h
Key-on resets LFO wave
0 - 1
{ 10 }
28h
cont = start
0 - 1
{ 11 }
29h
clock divide
0 - 24
{ 9 }
2Ah
thru / sync 24 / aux 2+3
0 - 2
0=thru / 1= sy24 / 2= aux 2+3
2Bh
Aux 2 controller #
251 > 0 > 119
{ 6 }
2Ch
Aux 2 controller #
251 > 0 > 119
{ 6 }
2Dh
Sysex Device Number 0 - 15
{ 1 } & { 12 }
{ NOTES }
{ 1 } Data 0 - 15 corresponds to MIDI channels or device numbers 1 - 16
{ 2 } 232 = -24 semitones 0 = no transpose 24 = + 24 semitones - 25 to 231 are invalid
{ 3 } 253=pmt off 254=pmt on 255=prg chng & 0 - 119
{ 4 } 252=ignore 253=pitchbend 254=velocity 255=aftertouch & 0 - 119
{ 5 } 0= -64 64=0 127=+63
{ 6 } 251=trig 252=ignore 253=p.bend 254=vel 255=aft & 0 - 119
{ 7 } 0= triangle 1= saw up 2= saw down 3= 10% pulse etc. as display
{ 8 } 1 - 96 corresponds to sync divide 1 to 96 and 0 = off
{ 9 } 0 - 23 corresponds to arpeggio divide 1 to 24
{ 10 } 0=off 1=on
{ 11 } 0 = continue ignored 1 = continue=start
{ 12 } WARNING – any messages after this will need to use the new device number
All sysex addresses and data are range checked and out-of-range values
will either be ignored or adjusted to give a valid response.