beautypg.com

Appendices ~ appendix c: serial commands, Terle – ClearOne AP10 User Manual

Page 31

background image

27

Appendices

~ Appendix C: Serial Commands

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

TERLE

This command reports back the telephone echo return loss enhancement (ERLE) for

the AP10 in dB. This is a read-only parameter.

Command form: DEVICE TERLE

Return values: If the current TERLE level for the telephone canceller is 20dB, the

following is returned out the serial port: DEVICE TERLE 20

UID

This command returns the unique ID number of the unit. This command is read-only.

Command form: DEVICE UID

Return values: UID returns the unit ID code. The Unit ID is composed of an eight-

digit hex number (assigned at the factory) to uniquely identify the unit.

Example:

To request the unit ID:

#20 UID

The following is returned out the serial port:

#20 UID A4EF906C

VER

This command returns current version of firmware. This version is unique to a

released version of firmware. This command is read-only.

Command form: DEVICE VER

Return values: VER returns the version of firmware (a major version number

followed by a period and a minor version number).

Example:

To request the unit ID from device 20

#20 VER

The following is returned out the serial port:

#20 VER 1.1