beautypg.com

Assigning device id numbers, Connecting power, Installation ~ hardware setup – ClearOne AP10 User Manual

Page 13: Device id dip switch settings

background image

9

Installation

~ Hardware Setup

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

If more than one AP10 is
assigned the same device
ID number, the Transmit

and Receive LEDs will flash red and
green on the affected units until the
error is corrected.

!

Assigning device ID numbers

Once your physical G-Link network is established, you need to set up unique G-Link

device ID numbers for each AP10 on the network. As shipped from the factory, all

AP10 units default as binary address 0. Set device ID numbers for each AP10 unit

at your site by manipulating front-panel DIP switches 9–12, selecting/deselecting

each switch to set up address 0–15 in binary code. Use the table below to determine

the proper DIP switch settings for the device ID you want to assign.

Connecting power

The power input [1] will operate at any level between 100–240VAC, 50–60Hz, 15W

(typical). Plug in the AP10 to complete the hardware installation.

Device ID DIP switch settings

Binary

DIP Switch 9

DIP Switch 10

DIP Switch 11

DIP Switch 12

Address

Position

Position

Position

Position

0

0 (DOWN)

0 (DOWN)

0 (DOWN)

0 (DOWN)

1

0 (DOWN)

0 (DOWN)

0 (DOWN)

1 (UP)

2

0 (DOWN)

0 (DOWN)

1 (UP)

0 (DOWN)

3

0 (DOWN)

0 (DOWN)

1 (UP)

1 (UP)

4

0 (DOWN)

1 (UP)

0 (DOWN)

0 (DOWN)

5

0 (DOWN)

1 (UP)

0 (DOWN)

1 (UP)

6

0 (DOWN)

1 (UP)

1 (UP)

0 (DOWN)

7

0 (DOWN)

1 (UP)

1 (UP)

1 (UP)

8

1 (UP)

0 (DOWN)

0 (DOWN)

0 (DOWN)

9

1 (UP)

0 (DOWN)

0 (DOWN)

1 (UP)

10 (A)

1 (UP)

0 (DOWN)

1 (UP)

0 (DOWN)

11 (B)

1 (UP)

0 (DOWN)

1 (UP)

1 (UP)

12 (C)

1 (UP)

1 (UP)

0 (DOWN)

0 (DOWN)

13 (D)

1 (UP)

1 (UP)

0 (DOWN)

1 (UP)

14 (E)

1 (UP)

1 (UP)

1 (UP)

0 (DOWN)

15 (F)

1 (UP)

1 (UP)

1 (UP)

1 (UP)