Assigning device id numbers, Connecting power, Installation ~ hardware setup – ClearOne AP10 User Manual
Page 13: Device id dip switch settings
9
Installation
~ Hardware Setup
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
If more than one AP10 is
assigned the same device
ID number, the Transmit
and Receive LEDs will flash red and
green on the affected units until the
error is corrected.
!
Assigning device ID numbers
Once your physical G-Link network is established, you need to set up unique G-Link
device ID numbers for each AP10 on the network. As shipped from the factory, all
AP10 units default as binary address 0. Set device ID numbers for each AP10 unit
at your site by manipulating front-panel DIP switches 9–12, selecting/deselecting
each switch to set up address 0–15 in binary code. Use the table below to determine
the proper DIP switch settings for the device ID you want to assign.
Connecting power
The power input [1] will operate at any level between 100–240VAC, 50–60Hz, 15W
(typical). Plug in the AP10 to complete the hardware installation.
Device ID DIP switch settings
Binary
DIP Switch 9
DIP Switch 10
DIP Switch 11
DIP Switch 12
Address
Position
Position
Position
Position
0
0 (DOWN)
0 (DOWN)
0 (DOWN)
0 (DOWN)
1
0 (DOWN)
0 (DOWN)
0 (DOWN)
1 (UP)
2
0 (DOWN)
0 (DOWN)
1 (UP)
0 (DOWN)
3
0 (DOWN)
0 (DOWN)
1 (UP)
1 (UP)
4
0 (DOWN)
1 (UP)
0 (DOWN)
0 (DOWN)
5
0 (DOWN)
1 (UP)
0 (DOWN)
1 (UP)
6
0 (DOWN)
1 (UP)
1 (UP)
0 (DOWN)
7
0 (DOWN)
1 (UP)
1 (UP)
1 (UP)
8
1 (UP)
0 (DOWN)
0 (DOWN)
0 (DOWN)
9
1 (UP)
0 (DOWN)
0 (DOWN)
1 (UP)
10 (A)
1 (UP)
0 (DOWN)
1 (UP)
0 (DOWN)
11 (B)
1 (UP)
0 (DOWN)
1 (UP)
1 (UP)
12 (C)
1 (UP)
1 (UP)
0 (DOWN)
0 (DOWN)
13 (D)
1 (UP)
1 (UP)
0 (DOWN)
1 (UP)
14 (E)
1 (UP)
1 (UP)
1 (UP)
0 (DOWN)
15 (F)
1 (UP)
1 (UP)
1 (UP)
1 (UP)