beautypg.com

Conair WSB User Manual

Page 81

background image

Occasionally, the system gets STUCK doing retries of a component but
the retry time is so short that nothing gets dispensed.
* The LAG TIME parameter is set for too short a time. See KEYPAD,
TIME, and PARAMETER, _LA.

* The dispense valve is sticking, slightly delaying it's opening.
The time period is too short for the valve to begin moving.

The system USED TO WORK but now it does unexplainable things.
* Static or a voltage surge has altered RAM memory. Do a CLEAR or
CLEAR ALL. See "CLEAR" RESTART or "CLEAR ALL" RESTART.
After a "CLEAR ALL", LOAD CELL CALIBRATION is necessary.

The Display reads 3100.0 even with the bin empty. This is the upper
limit load cell readout.

* The Load Cells are not plugged in and the circuitry has drifted
to the top limit.
* The load cells have been overloaded way beyond their limit and
are now permanently deflected.

Dispenses from a slide gate are not as consistent as they should be. *
The slide gate is sticking slightly. With the hopper empty, move
the slide manually to see that it moves freely. Press up or down on
the air cylinder to adjust for proper alignment.

* The material does not flow very well. A bridge breaker adaptor
may be required.

Load Cell weight readings are not holding steady. They vary as much as
100 grams from second to second.
* This is static and improper grounding. See WIRING CONSIDERATIONS
* If readings drift slowly in one direction, requiring frequent
recalibration, a component on the circuit board is most likely
faulty. Call us.
* If TARE weights are not steady, something may be physically

interfering with free movement of the cells.

The Weigh Bin dump valve does not stay open long enough for the bin to
empty fully.
* The air flow control valve is adjusted too far in and the valve
opens too slowly. This should be adjusted to slow the closing
just enough to prevent excessive banging.
* The DTI parameter is not set for enough dump time. This
parameter controls Dump Time (DTI). Recommended times are 2000
grams = 6 sec.; 4000 grams = 10 sec.; 9000 grams = 4 sec.

Entries are in seconds. See PARAMETERS for more information.

The MIX MOTOR runs when set to ON but not when set to TIMED.
* The fuse on the RELAY circuit board is blown. See hardware
maintenance for replacement instructions.

Page 82