beautypg.com

Conair WSB User Manual

Page 15

background image

RATE CALIBRATION

RATE CALIBRATION is probably not necessary. The software initially
expects STANDARD hardware. However, if you are using an auger feeder

on a model with four dispense valves, or a 1/2 inch auger instead of a
1" auger, the software will take 10 or 20 cycles to adjust to correct
operation. This slows down the process for a short time, but does not
effect accuracy.

If your hardware is STANDARD, or
you prefer letting the system SELF ADJUST,
you may:
+---------------------------------------------------+
¦ ¦

¦ PROCEED TO: NORMAL OPERATION NEXT PAGE ¦
¦ ¦
+---------------------------------------------------+

To perform a RATE CALIBRATION:

Have all HOPPERS LOADED with enough material to run for several cycles
without running out.

Have the "OFF AT END OF CYCLE" and "PAUSE" switches DOWN.

Press: * Display will say: (PASSWORD)
Press: 22222 Display will say: (P x)

If your system has auger feeders, operate them briefly to ensure they
are fully primed. To do so:

Press: OPER Display will say: (OPERATE )

Press: COL Run until auger is dispensing.
Press: ADD Run until auger is dispensing.
Press: DUMP This will empty the weigh bin.

Now you can CALIBRATE EACH material.
To do so:

Press: CAL Display will say: (CALIBRATE)
Press: REG REGRIND will calibrate itself.

For each material, press CAL followed by the proper component key.
Each time a dispense will occur, followed by weighing, followed by
a dump to empty the weigh bin.

Press: EXIT when all calibrations are done.

YOU ARE NOW READY FOR ACCURATE PRODUCTION BLENDING.

+---------------------------------------------------+
¦ ¦
¦ PROCEED TO: SPECIAL INSTRUCTIONS NEXT PAGE ¦
¦ ¦
+---------------------------------------------------+

Page 16