beautypg.com

Specifications – Interlogix NX-8 User Manual

Page 61

background image

SPECIFICATIONS

OPERATING POWER

16.5 VAC 25, 40, or 50 VA Transformer

AUXILIARY POWER

w/25 VA Transformer

12 VDC Regulated 500 mA

w/40 or 50 VA Transformer

12 VDC Regulated 1 AMP

w/NX-320E Power Supply

12 VDC Regulated 2 AMPS + Control

Panel Power

LOOP RESISTANCE

Standard Loop

300 Ohms Maximum

2-Wire Smokes

30 Ohms Maximum

BUILT-IN SIREN DRIVER

2-tone (Temporal and Yelp)

LOOP RESPONSE

Selectable 50mS or 500mS

OPERATING TEMPERATURE

32 to 120 degrees F

LED KEYPAD

Current Draw

130 mA max.

Zones Normal w/o Sounder

55 mA

Dimensions

6.4"

Wide

4.0" High

1.1" Deep

NX-148E LCD KEYPAD

Current Draw

110 mA max.

w/o Sounder

75 mA

Dimensions

6.4"

Wide

5.3" High

1.0" Deep

METAL ENCLOSURE DIMENSION

11.25" Wide

11.25" High

3.50" Deep

SHIPPING WEIGHT

9 lbs.
















Main Phone

800-727-2339

Technical Support

888-437-3287

Outside the US

903-845-6941

Sales & Literature

800-547-2556

Main Fax

903-845-6811

Web:

www.utcfireandsecurity.com



NX-8 INSTALLATION MANUAL
INX8IM

Rev B (MAY2011)

UL approved

for ANSI/SIA

CP-01-2000