NX-8 Control

44

LOC

PG

DESCRIPTION

DEFAULT

DATA

37

23

Segment #3 (Circle numbers to program)

1

2
3
4
5
6
7
8

Box Tamper report enabled.
AC Fail report enabled.
Low Battery report enabled.
Auxiliary power over current report enabled.
Siren supervision report enabled.
Telephone Line Cut report enabled.
Ground Fault Detection report enabled.
Expander trouble report enabled.

Segment #4 (Circle numbers to program)

1

2
3
4
5
6
7
8

Failure To Communicate report enabled.
Log Full report enabled.
Autotest report enabled.
Start and End Programming report enabled.
End Download report enabled.
Sensor Low Battery report enabled.
Sensor Missing report enabled.
Reserved.

Segment #5 (Circle numbers to program)

1

2

3

4

5

6

7
8

Lost Clock service LED enable.

Zone Doubling enable.

Disable on-board eight zones.

Enables two trips on the same cross-zone to activate the alarm.

Disables bypass reports for force armed zones

Reserved.

Clock uses internal crystal.

Disable Temporal Siren on Fire (Do not disable on UL listed systems)

38

23

SWINGER SHUTDOWN COUNT

1

_

KEYPAD SOUNDER CONTROL

Segment #1 (Circle numbers to program)

39

23

1

2

3

4
5
6
7
8

Keypad sounds for Telephone Line Cut when in the Armed state.

Keypad sounds for Telephone Line Cut when in the Disarmed state.

Keypad sounds upon AC Power Failure.

Keypad sounds upon Low Battery Detection.
Keypad sounds during Cross Zone Trip Time.
Keypad sounds for Tamper Alarm.

Reserved.

Keypad sounds for expander trouble (required for UL).

SYSTEM TIMERS

Segment #1 Dynamic Battery Test duration (0-255 minutes)

0

_

Segment #2 AC Failure report delay (0-255 minutes)

5

_

Segment #3 Power Up Delay (0-60 seconds)

60

_

Segment #4 Siren Time (1-254 minutes)

8

_

Segment #5 Telephone Line Cut delay (0-255 seconds)

0

_

Segment #6 Cross Zone Time (0-255 minutes)

5

_

Segment #7 Chime Time in 50 mS increments (0-255)

3

_

Segment #8 Dialer delay (15-255 seconds)

30

_

Segment #9 Fire Alarm Verification Time (120-255 sec.)

0

_

40


24

Segment #10 Listen-In Time (0-255 seconds)

0

_