Default zone types (configurations), E 20 – Interlogix NX-8 User Manual
Page 20
NX-8 Control
20
DEFAULT ZONE TYPES (Configurations)
Zones can be programmed to be one of twenty different zone types (configurations). Zone types # 17 - 20 can be used
for wireless or hardwired zones using European double EOL configuration. The default zone types are listed below.
These zone types can be customized by programming locations 110-149.
DATA
DESCRIPTION OF DEFAULT ZONE TYPES
"1"
DAY ZONE - Instant when system is armed trouble zone when system is disarmed.
"2"
24-HOUR AUDIBLE - Creates an instant yelping siren alarm regardless of the armed state of the control
panel.
"3"
ENTRY/EXIT DELAY 1- A trip will start entry delay 1. The lack of a trip during exit delay will enable the
Automatic Bypass or Instant mode if so programmed.
"4"
FOLLOWER WITH AUTO- BYPASS DISABLED - This zone will be instant when the system is armed
and no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will
not automatically bypass even if enabled in Segment 1 of Location 23.
"5"
INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED - This zone will be instant when the system
is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This
zone will automatically bypass if enabled in Segment 1 of Location 23.
"6"
INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on.
"7"
24-HOUR SILENT - Creates an instant silent alarm regardless of the armed state of the control panel. It
will not display on the keypad.
"8"
FIRE - This zone will light the Fire LED and sound the temporal siren each time the zone is shorted. It will
also rapidly flash the Fire LED indicating a trouble if the zone is open.
"9"
ENTRY/EXIT DELAY 2- A trip will start entry delay 2. The lack of a trip during exit delay will enable the
Automatic Bypass or Instant mode if so programmed.
"10"
24-HOUR SILENT SUPERVISED- Creates an instant silent alarm regardless of the armed state of the
control panel. It will display on the keypad.
"11"
KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel
that it resides in each time the zone is shorted. Keyswitch arming will report as user #99.
"12"
INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED - This zone will be instant when the system
is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. If a
"Cross Zone" is not being timed it will start a "Cross Zone" timer. If a "Cross Zone" is being timed it will
create an instant alarm. This zone will automatically bypass when enabled in Segment 1 of Location 23.
"13"
INSTANT ENTRY GUARD - This zone creates an instant alarm whenever it is tripped and the Stay LED
is off. It will start an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on.
"14"
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1. This zone will
bypass when the "Group Bypass" command is entered at the keypad. The lack of a trip during exit delay
will enable the Automatic Bypass or Instant mode if so programmed.
"15"
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system
is armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone
will bypass when the "Group Bypass" command is entered at the keypad. This zone will automatically
bypass if enabled in Segment 1 of Location 23.
"16"
INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is
tripped and the Armed LED is on. This zone will bypass when the "Group Bypass" command is entered at
the keypad.
"17"
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED- A trip will start entry delay 1. The lack of a trip
during exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type
can be used to enable tamper on a wireless transmitter.
"18"
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant
when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit
delay times. This zone will automatically bypass if enabled in Segment 1 of Location 23. This zone type
can be used to enable tamper on a wireless transmitter.
"19"
INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the
Armed LED is on. This zone type can be used to enable tamper on a wireless transmitter.
"20"
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-A trip will start entry delay 2. The lack of a trip
during exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type
can be used to enable tamper on a wireless transmitter.