Interlogix NX-8 User Manual
Page 40
NX-8 Control
40
1
2
3
4
5
6
7
8
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
LOC
PG
DESCRIPTION
DEFAULT
PROGRAMMING DATA
#3
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
13 16 PHONE #3, ACCOUNT CODE
10 - 10 - 10 - 10 - 10 - 10
_ _ _ _ _ _
14 16 PHONE #3, REPORTING FORMAT
0
_
15 17 PHONE #3, DIAL ATTEMPTS
BACKUP CONTROL
8
0
_
_
PHONE #3, SELECTING EVENTS TO REPORT TO PHONE #3
Segment #1 (Circle Numbers To Program)
Segment #2 (Circle Numbers To Program)
1
2
3
4
5
6
7
8
Alarms and Restores
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure or Low Battery)
Siren & Telephone Fault
Test Reports
Program, Download, & Log Full
1
2
3
4
5
6
7
8
Tampers
Short Circuit & Ground Fault
Sensor Lost
Sensor Low Battery
Expander Trouble
Failure To Communicate
Reserved
Reserved
PHONE #3, SELECTING WHICH PARTITIONS REPORT TO PHONE #3
Segment #1 (Circle Numbers To Program)
1
2
3
4
5
6
7
8
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
FORMAT OVERRIDE
Segment #1 (Circle Numbers To Program)
Segment #2 (Circle Numbers To Program)
1
2
3
4
5
6
7
8
On = 1800hz transmit; Off = 1900hz
On = 2300hz handshake; Off = 1400hz.
On =cksum parity; Off = double round parity
On = 2 digit event code; Off = 1 digit code
Reserved.
Reserved.
On = 20 p.p.s.; Off = 10 or 40 p.p.s.
On = 10 p.p.s.; Off = 20 or 40 p.p.s.
1
2
3
4
5
6
7
8
On = pager format (no handshake required)
On = 1400/2300 handshake
Reserved
Reserved
On = Contact ID
On = SIA
On = Contact ID or 4+3
On = DTMF
Segments #3 & #4 RESERVED
19 18 DOWNLOAD ACCESS CODE
8-4-8-0-0-0-0-0
_ _ _ _ _ _ _ _
20 18 RINGS TO ANSWER DOWNLOAD
8
_
DOWNLOAD CONTROL
21
Segment #1 (Circle Numbers To Program)