NX-8 Control

19

LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (3 segments, feature selection data)

Location 23 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in location 23. Each of these features can be enabled
by partition. For additional partition information see locations 88-109 on pages 32-35. If the feature selection
location for any partition is left blank, that partition will use this location for the feature selection.


This location contains 3 segments of 8 features each. (See the feature definitions beginning on page 5.)


Segment 1:

1 - On enables the Quick Arm feature.
2 - On enables the Re-exit feature.
3 - On enables the Automatic Bypass feature. Factory default is “enabled.”
4 - On enables the Silent Keypad Panic feature (overrides the audible panic selection).
5 - On enables the Audible Keypad Panic feature.
6 - On enables the Keypad Aux 1 feature (FIRE).
7 - On enables the Keypad Aux 2 feature (MEDICAL).
8 - On enables the Keypad Multiple Code Attempt Tamper feature.


Segment 2 :

1 - On enables the LED Extinguish feature.
2 - On enables the Require Code for Bypassing feature.
3 - On enables the Zone Bypassed Sounder Alert feature.
4 - On enables the AC Power/Low Battery Sounder Alert feature.
5 - On enables Bypass toggle.
6 - On enables Silent Auto Arm.
7 - On enables the Automatic Instant feature.
8 - Reserved.


Segment 3:

1 - On enables Opening and Closing reports.
2 - On enables Zone Bypass reporting.
3 - On enables Zone Restore reporting.
4 - On enables Zone Trouble reporting.
5 - On enables Zone Tamper reporting.
6 - On enables the Cancel reporting. Factory default is “enabled.”
7 - On enables the Recent Closing report. Factory default is “enabled.”
8 - On enables the Exit Error report. Factory default is “enabled.”

LOCATION 24 - ENTRY / EXIT TIMERS (4 segments, numerical data)

Location 24 is used to program the Entry/Exit times. There are 2 separate Entry/Exit times.

Segment 1, Entry time 1:

This is the entry time that will be used when a delay 1 zone type initiates an
entry delay. Valid entries are 30-255 seconds.

Segment 2, Exit time 1:

This is the exit time that will be used for all zones designated as delay 1. Valid
entries are 45-255 seconds.

Segment 3, Entry time 2:

This is the entry time that will be used when a delay 2 zone type initiates an
entry delay. Valid entries are 30-255 seconds.

Segment 4, Exit time 2:

This is the exit time that will be used for all zones designated as delay 2. Valid
entries are 45-255 seconds.