Interlogix NX-8 User Manual
Page 36
NX-8 Control
36
LOCATION 115 - ZONE TYPE 3 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 116 - ZONE TYPE 4 ALARM EVENT CODE (1 segment, numerical data)
Location 116 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 116 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 117 - ZONE TYPE 4 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 118 - ZONE TYPE 5 ALARM EVENT CODE (1 segment, numerical data)
Location 118 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 118 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 119 - ZONE TYPE 5 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 120 - ZONE TYPE 6 ALARM EVENT CODE (1 segment, numerical data)
Location 120 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 120 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 121 - ZONE TYPE 6 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 122 - ZONE TYPE 7 ALARM EVENT CODE (1 segment, numerical data)
Location 122 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 54.The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 122 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 123 - ZONE TYPE 7 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 124 - ZONE TYPE 8 ALARM EVENT CODE (1 segment, numerical data)
Location 124 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 124 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 125 - ZONE TYPE 8 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 126 - ZONE TYPE 9 ALARM EVENT CODE (1 segment, numerical data)
Location 126 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 126 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 127 - ZONE TYPE 9 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 128 - ZONE TYPE 10 ALARM EVENT CODE (1 segment, numerical data)
Location 128 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 128 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.