Interlogix NX-8 User Manual
Page 51
NX-8 Control
51
LOC
PG
DESCRIPTION
DEFAULT
DATA
PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1
Segment #2
Segment #3
108 34
1
2
3
4
5
6
7
8
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
1
2
3
4
5
6
7
8
LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved
1
2
3
4
5
6
7
8
Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error
109
35 PARTITION 8, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
0
_
Segment #2 (Exit Time #1)
0
_
Segment #3 (Entry Time #2)
0
_
Segment #4 (Exit Time #2)
0
_
110
35 ZONE TYPE 1 ALARM EVENT CODE
8
_
111
35 ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1 (Circle numbers to program)
1
2
3
4
Fire (enable for fire zone).
24 Hour (enable for non-fire 24 hour
zone).
Keyswitch zone.
Follower (enable for burg zones that are
instant during non-entry times).
5
6
7
8
Delay 1 zone (enable to follow Timer 1 Entry/Exit
times).
Delay 2 zone (enable to follow Timer 2 Entry / Exit
times).
Interior (Enable for auto bypass or stay arming).
Local Only (enable if zone is not to be reported).
Segment #2 (Circle numbers to program)
1
2
3
4
Keypad audible on alarm.
Yelping siren on alarm.
Temporal siren on alarm.
Chime.
5
6
7
8
Bypassable.
Group Shunt.
Force armable.
Entry Guard.
Segment #3 (Circle numbers to program)
1
2
3
4
Fast Loop Response.
Double End of Line Tamper zone.
Trouble zone (Day zone).
Cross Zone.
5
6
7
8
Dialer Delay zone.
Swinger zone.
Restore reporting.
Listen-In.
THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF
EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM LOCATION 111 TO UNDERSTAND
THESE DEFAULTS.
112
ZONE TYPE 2 ALARM EVENT CODE
2
_
113
ZONE TYPE 2 CHARACTERISTIC SELECT
2-125-78
114
ZONE TYPE 3 ALARM EVENT CODE
7
_
115
ZONE TYPE 3 CHARACTERISTIC SELECT
5-1245-5678
116
ZONE TYPE 4 ALARM EVENT CODE
5
_
117
ZONE TYPE 4 CHARACTERISTIC SELECT
45-125-5678
118
ZONE TYPE 5 ALARM EVENT CODE
5
_
119
ZONE TYPE 5 CHARACTERISTIC SELECT
457-125-5678
120
ZONE TYPE 6 ALARM EVENT CODE
4
_
121
ZONE TYPE 6 CHARACTERISTIC SELECT
0-1245-5678
122
ZONE TYPE 7 ALARM EVENT CODE
0
_
123
ZONE TYPE 7 CHARACTERISTIC SELECT
2-0-78
124
ZONE TYPE 8 ALARM EVENT CODE
1
_
125
ZONE TYPE 8 CHARACTERISTIC SELECT
1-13-378