beautypg.com

Interlogix NX-8 User Manual

Page 51

background image

NX-8 Control

51

LOC

PG

DESCRIPTION

DEFAULT

DATA

PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1

Segment #2

Segment #3

108 34

1
2
3
4
5
6
7
8

Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper

1
2
3
4
5
6
7
8

LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved

1
2
3
4
5
6
7
8

Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error

109

35 PARTITION 8, ENTRY/EXIT TIMERS

Segment #1 (Entry Time #1)

0

_

Segment #2 (Exit Time #1)

0

_

Segment #3 (Entry Time #2)

0

_

Segment #4 (Exit Time #2)

0

_

110

35 ZONE TYPE 1 ALARM EVENT CODE

8

_

111

35 ZONE TYPE 1 CHARACTERISTIC SELECT

Segment #1 (Circle numbers to program)



1
2

3
4

Fire (enable for fire zone).
24 Hour (enable for non-fire 24 hour
zone).
Keyswitch zone.
Follower (enable for burg zones that are
instant during non-entry times).

5

6

7
8

Delay 1 zone (enable to follow Timer 1 Entry/Exit
times).
Delay 2 zone (enable to follow Timer 2 Entry / Exit
times).
Interior (Enable for auto bypass or stay arming).
Local Only (enable if zone is not to be reported).

Segment #2 (Circle numbers to program)

1
2
3
4

Keypad audible on alarm.
Yelping siren on alarm.

Temporal siren on alarm.
Chime.

5
6
7
8

Bypassable.
Group Shunt.
Force armable.
Entry Guard.

Segment #3 (Circle numbers to program)

1
2
3
4

Fast Loop Response.
Double End of Line Tamper zone.
Trouble zone (Day zone).
Cross Zone.

5
6
7
8

Dialer Delay zone.
Swinger zone.
Restore reporting.
Listen-In.

THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF

EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM LOCATION 111 TO UNDERSTAND

THESE DEFAULTS.

112

35

ZONE TYPE 2 ALARM EVENT CODE

2

_

113

35

ZONE TYPE 2 CHARACTERISTIC SELECT

2-125-78

114

35

ZONE TYPE 3 ALARM EVENT CODE

7

_

115

36

ZONE TYPE 3 CHARACTERISTIC SELECT

5-1245-5678

116

36

ZONE TYPE 4 ALARM EVENT CODE

5

_

117

36

ZONE TYPE 4 CHARACTERISTIC SELECT

45-125-5678

118

36

ZONE TYPE 5 ALARM EVENT CODE

5

_

119

36

ZONE TYPE 5 CHARACTERISTIC SELECT

457-125-5678

120

36

ZONE TYPE 6 ALARM EVENT CODE

4

_

121

36

ZONE TYPE 6 CHARACTERISTIC SELECT

0-1245-5678

122

36

ZONE TYPE 7 ALARM EVENT CODE

0

_

123

36

ZONE TYPE 7 CHARACTERISTIC SELECT

2-0-78

124

36

ZONE TYPE 8 ALARM EVENT CODE

1

_

125

36

ZONE TYPE 8 CHARACTERISTIC SELECT

1-13-378