Interlogix Concord Express Installation Manual User Manual
Page 59
Chapter 2
Concord Express Installation Instructions
53
Swinger Limit (05014)
Reporting-Global (Default=1)
This setting determines the maximum number of
times a sensor or zone can go into alarm (during
a single arming period) before the panel
automatically bypasses that sensor or zone. This
feature only applies to sensors in groups 00-20,
29, or 34.
When set to 1, the panel automatically bypasses
a sensor or zone after it causes an alarm. When
set to 2, the panel waits until a sensor or zone
has caused a second alarm (during the same
arming period) before bypassing it. At either
setting, the automatic bypass is logged into the
event buffer.
A bypassed zone or sensor will be cleared
(automatically “unbypassed”) if the system
receives no further activations from that sensor
or zone over the next 48-50 hours.
Changing the arming level also clears all
automatically bypassed sensors and zones and
resets the Swinger Limit count on all sensors and
zones.
To set the Swinger Limit:
1. With the display showing SWINGER LIMIT
n (current setting), press 1 or 2. The display
flashes the entered setting.
2. Press # and the display shows the new
setting.
The following describes how to program the settings that appear under
REPORTING—PARTITION 1.
Opening Reports (0510)
Reporting-Partition 1 (Default=off)
This setting determines whether or not
the panel sends an opening report to the
central station (or pager) after disarming
the system.
Note
: To use this feature, the
Open/Close Reports settings under the
PHONES—CS PHONE 1-2 and/or
PHONES—PAGER PHONE 1-3 menus
must be turned on for the specific CS
Phone or Pager Phone number.
To turn Opening Reports off or on:
1. With the display showing OPENING REPORTS
OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.