Chapter 5 troubleshooting – Interlogix DSGH Series User Manual
Page 21
GE-DSG-8 DSGH-5 and 8 Ethernet Switch User Manual
17
Chapter 5
Troubleshooting
This chapter contains information to help you solve common issues. If the Industrial
Gigabit Ethernet Switch is not functioning properly, make sure the Industrial Gigabit
Ethernet Switch was set up according to instructions in this manual.
The per port LED is not lit
Solution:
Check the cable connection of the Industrial Gigabit Ethernet Switch.
Performance is bad
Solution:
Check the speed duplex mode of the partner device. The Industrial Gigabit Ethernet
Switch is run at Auto-negotiation mode and if the partner is set to half duplex, then
the performance will be poor.
Per port LED is lit, but the traffic is irregular
Solution:
Check that the attached device is not set to dedicate full duplex. Some devices use a
physical or software switch to change duplex modes. Auto-negotiation may not
recognize this type of full-duplex setting.
Why the Industrial Gigabit Ethernet Switch doesn't connect to the network
Solution:
Check per port LED on the Industrial Gigabit Ethernet Switch. Try another port on the
Industrial Gigabit Ethernet Switch Make sure the cable is installed properly Make sure
the cable is the right type Turn off the power. After a minnute, turn on the power
again.