Cabletron Systems 2E48-27R User Manual
Page 41

Using LANVIEW
2E48-27R/2E49-27R User’s Guide
4-3
RX
(Receive)
Off
No link. No activity.
Port enabled or
disabled.
No error.
Green
Solid. Port enabled,
link, no activity.
No error.
Blinking. Port
disabled, link.
No error.
Amber
Flashing. Port
enabled, link, activity.
No error.
Red
Diagnostic failure.
Contact the Cabletron
Systems GCC for assistance.
TX
(Transmit)
Off
Port enabled, and no
activity.
Should flash green
every two seconds
indicating BPDUs
being sent if STA is
enabled and there is a
valid link.
1. Ensure that the STA is
enabled and that there is a
valid link.
2. Contact the Cabletron
Systems GCC for
assistance.
Green
Flashing. Indicates
activity. Rate indicates
data rate.
No action.
Amber
Blinking. Port in
standby.
Port may be disabled
due to Spanning Tree.
1. Ensure that the port is not
disabled.
2. Contact the Cabletron
Systems GCC for
assistance.
Red
Flashing. Indicates
collision rate.
No action.
Solid. Diagnostic
failure.
Contact the Cabletron
Systems GCC for assistance.
Table 4-1
LANVIEW LEDs (Continued)
LED
Color
State
Recommended Action