Removing the Chassis Cover

2E48-27R/2E49-27R User’s Guide

C-5

Figure C-2

2E4X-27R Mode Switch Location/Component Layout

Switch 6 – Forced BootP.

DO NOT attempt a Forced BootP unless a BootP server has been
configured for the 2E4X-27R. The BootP server references the
location of a station acting as a Trivial File Transfer Protocol (TFTP)
server containing the 2E4X-27R image file.

When the position of Switch 6 is changed and the power is cycled to
the 2E4X-27R, the device requests the image file location from the
BootP server and uses TFTP to download the image from the TFTP
server. If one of these requirements is not met, the 2E4X-27R
continues to request either the BootP server or the TFTP server until
the RESET button on the 2E4X-27R is pressed. Once the RESET
button is pressed, the 2E4X-27R resets after one minute and loads the
image stored in FLASH memory.

NOTE

After changing the position of switch 6, DO NOT reapply power
to the chassis until there is a station on the network acting as a
PootP server, which contains the image file.

23141-05

Flash

DRAM

MODE SWITCH BANK

1

2

3

4

5

6

7

8

OFF

ON

FRONT PANEL

TOP VIEW WITHOUT COVER

Primary
Power
Supply

Redundant
Power
Supply