Scope of delivery, Available accessoires – Flintec II PC-BASED User Manual
Page 6

FlintWeigh Technical Manual, Rev. 3.03 November 2011
Page 6 of 32
Fig. 3.2: Connection of standard load cells via KAL-4 junction box with integrated LDU
Fig. 3.3: Block diagram with standard load cells and 2 scales
3.3. Scope of Delivery
►
Type FW-01 Scale Interface
►
Suitable plug connectors for the load cells and the digital I/O
►
FlintWeigh II Software
►
This manual
►
A medium (CD-ROM) with the FlintWeigh II software, the technical manual, the test certificates of the
LDUs, the FlintWeigh II EC type approval, some examples for using the OLE functions and a template
for the scale’s descriptive plate in RTF format
3.4. Available Accessoires
►
Type KPFD-8 junction box for type RC3D digital load cells
►
Type LDU 68.1 / 68.2 / 69.1 / 78.1 digital amplifiers for standard load cells
►
Type KAL-4 digital junction box
KAL-4
Digital I/O
12 V DC Supply
Type FW-01
Scale Interface
Standard Load Cells
Alibi memory
KAL-4
KAL-4
Standard Load Cells
Standard Load Cells
Digital I/O
12 V DC Supply
Alibi memory
Type FW-01
Scale Interface