Flintec II PC-BASED User Manual
Page 30

FlintWeigh Technical Manual, Rev. 3.03 November 2011
Page 30 of 32
Function
Description
Regist
Register the current weight value – Format 1
Return value
Value range
Format: string, 16 digits:
“rrrrrr nnnnnnn dd w” with
rrrrrr
Record no., 6 digits
000001, 000002, 000003...
nnnnnnn
Weight value including
decimal point, 7 digits
0...800 000
dd
Weight unit, 2 digits
g, kg, t, lb
w
Scale no., 1 digit
1 (scale 1); 2 (scale 2); 3 (dual scale)
Hint: Unused places within the weight value will be filled with spaces.
Attention: In legal for trade operation an entry to the alibi memory will be created and the
record counter will be incremented by one.
If a recording is not possible, a 2-digit error code will be notified:
E1
Scale in motion
E4
No zero crossing
E2
Weight value
≤
0
E5
Open input (tilt)
E3
Gros weight < minimum load
E6
Overload, etc.
Regist2
Register the current weight value – Format 2
Return value
Value range
Format: string, 30 digits:
“w_rrrrrr_nnnnnnn_kk_ttttttt_dd“ with
w
Scale no., 1 digit
1 (scale 1); 2 (scale 2); 3 (dual scale)
rrrrrr
Record no., 6 digits
000001, 000002, 000003...
nnnnnnn
Weight value including
decimal point, 7 digits
0...800 000
kk
Tare indication
„ “ (no tare); „ T“ (normal tare);
„PT“ (manual tare entry)
ttttttt
Tare value including
decimal point, 7 digits
0...800 000
dd
Weight unit, 2 digits
g, kg, t, lb
Hint: Unused places within the weight value will be filled with spaces.
Attention: In legal for trade operation an entry to the alibi memory will be created and the
record counter will be incremented by one.
If a recording is not possible, a 2-digit error code will be notified:
E1
Scale in motion
E4
No zero crossing
E2
Weight value
≤
0
E5
Open input (tilt)
E3
Gros weight < minimum load
E6
Overload, etc.
Param(w)
Read scale parameters
Parameter
Type
Use
w
Integer
w = 1 (scale 1); w = 2 (scale 2); w = 3 (dual scale)
Return value
Value range
Format: string, 17 digits:
"w_t_z1_z2_z3_k_dd" with
w
Scale no., 1 digit
1 (scale 1); 2 (scale 2); 3 (dual scale)
t
Scale type, 1 digit
1 (single-interval), 2 (multi-range), 3 (multi-interval)
z1
Scale interval 1, 2 digits
01, 02, 05, 10, 20, 50
z2
Scale interval 2, 2 digits
02, 05, 10, 20, 50 (at single-interval: 01)
Z3
Scale interval 3, 2 digits
05, 10, 20, 50 (at single-interval: 01)
k
Decimal places, 1 digit
1, 2, 3, 4, 5
dd
Weight unit, 2 digits
g, kg, t, lb